Difference between revisions of "Energy Storage Roadmap: Vision for 2025"
(using second level headings, as recommended by mediawiki format styling documentation) |
|||
(8 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
Energy storage is essential to a modern | <!-- ==About EPRI's Energy Storage Roadmap== --> | ||
Energy storage is essential to a clean and modern electricity grid and is positioned to enable the ambitious goals for renewable energy and power system resilience. EPRI's Energy Storage & Distributed Generation team and its Member Advisors developed the Energy Storage Roadmap to guide EPRI's efforts in advancing safe, reliable, affordable, and clean energy storage. First established in [https://www.epri.com/research/products/000000003002019722 2020] and founded on [https://www.epri.com/research/products/000000003002023456 EPRI's Mission] of '''advancing safe, reliable, affordable, and clean energy for society...''',the Energy Storage Roadmap envisioned a desired future for energy storage applications and industry practices in 2025 and identified the challenges in realizing that vision. The Energy Storage Roadmap was reviewed and [https://www.epri.com/research/products/000000003002024676 updated in 2022] to refine the envisioned future states and provide more comprehensive assessments and descriptions of the progress needed (i.e., gaps) to achieve the desired 2025 vision. | |||
=Defining the Desired Future States for 2025= | ==Energy Storage 2030== | ||
[[File:Roadmap30.png | right | 800px]] | |||
<q><span style="color:#00B4F1;">'''SAFE'''</span>, <span style="color:#38BC8D;">'''RELIABLE'''</span>, <span style="color:#A3C030;">'''AFFORDABLE'''</span>, and <span style="color:#F5B412;">'''CLEAN'''</span> '''Energy Storage''' is essential to the future of the electric system for Everyone, Everywhere, All the Time.</q> | |||
In 2024, EPRI and its Member Advisors are re-'''VISION'''-ing the desired future of energy storage in 2030. Based on the feedback and suggestions of both EPRI Advisors and subject matter experts (SMEs), the Energy Storage Roadmap will be simplified to its core pillars of <q><span style="color:#00B4F1;">'''SAFE'''</span>, <span style="color:#38BC8D;">'''RELIABLE'''</span>, <span style="color:#A3C030;">'''AFFORDABLE'''</span>, and <span style="color:#F5B412;">'''CLEAN'''</span>.</q> <span style="color:#F47933;">'''INNOVATION'''</span>, which was a pillar in ''EPRI's Energy Storage Roadmap | Vision for 2025'', is now embedded within each Roadmap pillar as a reflection of its role, operationally. At its core, <span style="color:#F47933;">'''INNOVATION'''</span> drives energy storage advancement in <span style="color:#00B4F1;">'''SAFETY'''</span>, <span style="color:#38BC8D;">'''RELIABILITY'''</span>, <span style="color:#A3C030;">'''AFFORDABILITY'''</span>, and <span style="color:#F5B412;">'''CLEAN'''</span> life cycle deployment. As such, inclusion of equity and workforce development are critical to advancement, and therefore embedded within <span style="color:#F47933;">'''INNOVATION'''</span>. Throughout the year, EPRI and its Member Advisors will assess the current state of energy storage within each pillar and reevaluate the gaps in industry knowledge and resources between now and the re-'''VISION'''-ed future for 2030. | |||
<!-- | |||
<blockquote style="background-color: gainsboro; border: solid thin grey;"> | |||
'''[https://www.epri.com/research/products/000000003002024676 Download the Energy Storage Roadmap: Vision for 2025 report here!]''' | |||
</blockquote> | |||
==Defining the Desired Future States for 2025== | |||
For more information, click on a future state in the image below: | For more information, click on a future state in the image below: | ||
<div class="responsive-imagemap"> | |||
<imagemap> | <imagemap> | ||
File:Target Future States | File:Target Future States Table_2.jpeg|none|thumb|800px|These target future states were collaboratively developed as visions for the beneficial use of energy storage. Clicking on each individual desired state will show the gaps identified to achieving these states. | ||
rect | rect 8 4 420 452 [[Energy Storage Roadmap: Vision for 2025/Safety|Safety]] | ||
rect | rect 4 472 424 672 [[Energy Storage Roadmap: Vision for 2025/Safety#Safety Practices Established|Safety Practices Established]] | ||
rect | rect 4 684 420 872 [[Energy Storage Roadmap: Vision for 2025/Safety#Asset Hazards Characterized and Minimized|Asset Hazards Characterized and Minimized]] | ||
rect | rect 4 884 424 1152 [[Energy Storage Roadmap: Vision for 2025/Safety#Community Resilience and Public Safety Applications Viable|Community Resilience and Public Safety Applications Viable]] | ||
rect | rect 436 4 856 456 [[Energy Storage Roadmap: Vision for 2025/Electric Reliability|Electric Reliability]] | ||
rect | rect 436 472 852 664 [[Energy Storage Roadmap: Vision for 2025/Electric Reliability#Energy Storage Asset Reliability Characterized and Enhanced|Energy Storage Asset Reliability Characterized and Enhanced]] | ||
rect | rect 436 676 852 868 [[Energy Storage Roadmap: Vision for 2025/Electric Reliability#Energy Storage Controls Integrated and Interoperable|Energy Storage Controls Integrated and Interoperable]] | ||
rect | rect 440 880 840 1140 [[Energy Storage Roadmap: Vision for 2025/Electric Reliability#Energy Storage Integrated into Grid Planning and Portfolio Management|Energy Storage Integrated into Grid Planning and Portfolio Management]] | ||
rect | rect 864 4 1280 452 [[Energy Storage Roadmap: Vision for 2025/Economics|Economics]] | ||
rect | rect 864 460 1280 672 [[Energy Storage Roadmap: Vision for 2025/Economics#Planning and Operational Modeling Validated and Applied|Planning and Operational Modeling Validated and Applied]] | ||
rect | rect 864 680 1284 876 [[Energy Storage Roadmap: Vision for 2025/Economics#Multi-Use Applications Enabled|Multi-Use Applications Enabled]] | ||
rect | rect 856 880 1280 1144 [[Energy Storage Roadmap: Vision for 2025/Economics#Total Cost of Ownership Reduced|Total Cost of Ownership Reduced]] | ||
rect | rect 1296 8 1712 460 [[Energy Storage Roadmap: Vision for 2025/Environmental Responsibility|Environmental Responsibility]] | ||
rect | rect 1292 464 1716 684 [[Energy Storage Roadmap: Vision for 2025/Environmental Responsibility#Reduced Emissions with Energy Storage Applications|Reduced Emissions with Energy Storage Applications]] | ||
rect | rect 1288 692 1708 868 [[Energy Storage Roadmap: Vision for 2025/Environmental Responsibility#Sustainable Life Cycle Implemented|Sustainable Life Cycle Implemented]] | ||
rect | rect 1292 876 1712 1144 [[Energy Storage Roadmap: Vision for 2025/Environmental Responsibility#End-of-Life Impacts Minimized|End-of-Life Impacts Minimized]] | ||
rect 1728 8 2140 456 [[Energy Storage Roadmap: Vision for 2025/Innovation|Innovation]] | |||
rect 1728 464 2140 676 [[Energy Storage Roadmap: Vision for 2025/Innovation#Technology Advancements Accelerated|Technology Advancements Accelerated]] | |||
rect 1724 680 2144 868 [[Energy Storage Roadmap: Vision for 2025/Innovation#Future Workforce Available and Trained|Future Workforce Available and Trained]] | |||
rect 1728 876 2144 1148 [[Energy Storage Roadmap: Vision for 2025/Innovation#Cross-Industry Breakthroughs Tracked and Integrated|Cross-Industry Breakthroughs Tracked and Integrated]] | |||
</imagemap> | </imagemap> | ||
</div> | |||
--> | |||
=Energy Storage Roadmap | ==The Energy Storage Roadmap in Practice== | ||
The | Since its inception, the EPRI Energy Storage Roadmap was intended to guide the direction of EPRI's energy storage efforts to ensure delivery of relevant and impactful resources to its Members, the industry, and the public. The following table maps EPRI's energy storage related publications to the relevant [https://www.epri.com/research/products/000000003002024676 Future State]. The table may be sorted by column or filtered using the search box. If you encounter any issues with the content on this page or have any suggestions, please email [mailto:tkelly@epri.com Taylor Kelly]. | ||
{{#ask: | {{#ask: | ||
Line 48: | Line 62: | ||
|?Has Program Year=Year | |?Has Program Year=Year | ||
|?Has Is Public=Free to Public? | |?Has Is Public=Free to Public? | ||
|headers=show | |||
|format=table | |format=table | ||
|class=datatable | |class=datatable | ||
}} | }} | ||
Revision as of 00:36, 10 April 2024
Energy storage is essential to a clean and modern electricity grid and is positioned to enable the ambitious goals for renewable energy and power system resilience. EPRI's Energy Storage & Distributed Generation team and its Member Advisors developed the Energy Storage Roadmap to guide EPRI's efforts in advancing safe, reliable, affordable, and clean energy storage. First established in 2020 and founded on EPRI's Mission of advancing safe, reliable, affordable, and clean energy for society...,the Energy Storage Roadmap envisioned a desired future for energy storage applications and industry practices in 2025 and identified the challenges in realizing that vision. The Energy Storage Roadmap was reviewed and updated in 2022 to refine the envisioned future states and provide more comprehensive assessments and descriptions of the progress needed (i.e., gaps) to achieve the desired 2025 vision.
Energy Storage 2030
SAFE, RELIABLE, AFFORDABLE, and CLEAN Energy Storage is essential to the future of the electric system for Everyone, Everywhere, All the Time.
In 2024, EPRI and its Member Advisors are re-VISION-ing the desired future of energy storage in 2030. Based on the feedback and suggestions of both EPRI Advisors and subject matter experts (SMEs), the Energy Storage Roadmap will be simplified to its core pillars of SAFE, RELIABLE, AFFORDABLE, and CLEAN.
INNOVATION, which was a pillar in EPRI's Energy Storage Roadmap | Vision for 2025, is now embedded within each Roadmap pillar as a reflection of its role, operationally. At its core, INNOVATION drives energy storage advancement in SAFETY, RELIABILITY, AFFORDABILITY, and CLEAN life cycle deployment. As such, inclusion of equity and workforce development are critical to advancement, and therefore embedded within INNOVATION. Throughout the year, EPRI and its Member Advisors will assess the current state of energy storage within each pillar and reevaluate the gaps in industry knowledge and resources between now and the re-VISION-ed future for 2030.
The Energy Storage Roadmap in Practice
Since its inception, the EPRI Energy Storage Roadmap was intended to guide the direction of EPRI's energy storage efforts to ensure delivery of relevant and impactful resources to its Members, the industry, and the public. The following table maps EPRI's energy storage related publications to the relevant Future State. The table may be sorted by column or filtered using the search box. If you encounter any issues with the content on this page or have any suggestions, please email Taylor Kelly.