Difference between revisions of "Failure Event - China, Beijing - 16 Apr 2021"
Jump to navigation
Jump to search
Line 60: | Line 60: | ||
|Has Integrator= | |Has Integrator= | ||
|Has Application=Solar Integration | |Has Application=Solar Integration | ||
|Has Installation= | |Has Installation=Commercial | ||
|Has Enclosure Type=Container | |Has Enclosure Type=Container | ||
|Has Event Date=04/16/2021 | |Has Event Date=04/16/2021 | ||
|Has System Age (yr)=2.0 | |Has System Age (yr)=2.0 | ||
|Has Extent of Damage= | |Has Extent of Damage=Explosion | ||
|Has State During Accident=Construction, Commissioning | |Has State During Accident=Construction, Commissioning | ||
|Has Event Description= | |Has Event Description=A fire broke out at a BESS located on the roof of a shopping mall. An explosion occurred, killing two firefighters and injuring a third. | ||
|Has Source=[https:// | |Has Source=[https://epri.box.com/s/s8mj93w4md9dng0wygznqrolcpjm7z2r Investigation Report (English Translation)] | ||
|Has Additional Resources= | |Has Additional Resources= | ||
|Has Failure Event Category=ESS | |Has Failure Event Category=ESS |
Revision as of 12:38, 10 April 2024
Overview
Event Details | |
---|---|
Location: | China, Beijing |
Capacity (MW): | |
Capacity (MWh): | 25 |
Battery Module: | Gotion High-Tech [LFP] |
Integrator: | |
Application: | Solar Integration |
Installation: | Commercial |
Enclosure Type: | Container |
Event Date: | 16 April 2021 |
System Age (yr): | 2 |
Extent of Damage: | Explosion |
State During Accident: | Construction, Commissioning |
Description: | A fire broke out at a BESS located on the roof of a shopping mall. An explosion occurred, killing two firefighters and injuring a third. |
Source: | Investigation Report (English Translation) |
Additional Resources: |
- Note: Missing values in this table reflect unknowns.
If you have any details or corrections you would like to contribute to the database please reach out to our Storage Safety email.