Difference between revisions of "Failure Event - South Korea, Gunwi-gun, Gyeongsangbuk-do - 17 Jan 2022"
Jump to navigation
Jump to search
(4 intermediate revisions by the same user not shown) | |||
Line 41: | Line 41: | ||
! Description: | ! Description: | ||
| {{#show: {{FULLPAGENAME}} |?Has Event Description}} | | {{#show: {{FULLPAGENAME}} |?Has Event Description}} | ||
|- | |||
! Root Cause: | |||
| {{#show: {{FULLPAGENAME}} |?Has Root Cause}} | |||
|- | |||
! Failed Element: | |||
| {{#show: {{FULLPAGENAME}} |?Has Failed Element}} | |||
|- | |- | ||
! Source: | ! Source: | ||
Line 60: | Line 66: | ||
|Has Integrator= | |Has Integrator= | ||
|Has Application=Solar integration | |Has Application=Solar integration | ||
|Has Installation= | |Has Installation=Rural | ||
|Has Enclosure Type= | |Has Enclosure Type= | ||
|Has Event Date=01/17/2022 | |Has Event Date=01/17/2022 | ||
Line 67: | Line 73: | ||
|Has State During Accident=Operation. Fully charged | |Has State During Accident=Operation. Fully charged | ||
|Has Event Description= | |Has Event Description= | ||
|Has Root Cause=Manufacturing | |||
|Has Failed Element=Controls | |||
|Has Source=[https://www-e2news-com.translate.goog/news/articleView.html?idxno=239023&_x_tr_sl=auto&_x_tr_tl=en&_x_tr_hl=en-US&_x_tr_pto=wapp E2News] | |Has Source=[https://www-e2news-com.translate.goog/news/articleView.html?idxno=239023&_x_tr_sl=auto&_x_tr_tl=en&_x_tr_hl=en-US&_x_tr_pto=wapp E2News] | ||
|Has Additional Resources= | |Has Additional Resources= |
Latest revision as of 18:24, 16 May 2024
Overview
Event Details | |
---|---|
Location: | South Korea, Gunwi-gun, Gyeongsangbuk-do |
Capacity (MW): | 0.45 |
Capacity (MWh): | 1.5 |
Battery Module: | LG Energy Solution |
Integrator: | |
Application: | Solar integration |
Installation: | Rural |
Enclosure Type: | |
Event Date: | 17 January 2022 |
System Age (yr): | 3 |
Extent of Damage: | Fully burnt. Explosion |
State During Accident: | Operation. Fully charged |
Description: | |
Root Cause: | Manufacturing |
Failed Element: | Controls |
Source: | E2News |
Additional Resources: |
- Note: Missing values in this table reflect unknowns.
If you have any details or corrections you would like to contribute to the database please reach out to our Storage Safety email.