Difference between revisions of "Failure Event - South Korea, Gunwi - 29 Sep 2019"
Jump to navigation
Jump to search
(Created page with "=Overview= {| class="wikitable" style="width: 50%; font-size: 90%; border: 1px solid #aaaaaa; background-color: #f9f9f9; color: black; margin-bottom: 0.5em; margin-left: 1em; padding: 0.2em; float: center; clear: left; text-align:left;" ! style="text-align: center; background-color:#ccccff;" colspan="2" |<span style="font-size: larger;">Event Details14px|link=Special:Browse/{{FULLPAGENAME}} |- ! Location: | {{#show: {{FULLPAGENAME}} |?Has Loc...") |
|||
Line 64: | Line 64: | ||
|Has Event Date=09/29/2019 | |Has Event Date=09/29/2019 | ||
|Has System Age (yr)=1.8 | |Has System Age (yr)=1.8 | ||
|Has Extent of Damage= | |Has Extent of Damage=Fire | ||
|Has State During Accident=Discharging | |Has State During Accident=Discharging | ||
|Has Event Description=Smoke of an unknown cause occurred in | |Has Event Description=Smoke of an unknown cause occurred in |
Revision as of 12:38, 10 April 2024
Overview
Event Details | |
---|---|
Location: | South Korea, Gunwi |
Capacity (MW): | |
Capacity (MWh): | 1.5 |
Battery Module: | |
Integrator: | |
Application: | Solar Integration |
Installation: | Mountains |
Enclosure Type: | Prefab |
Event Date: | 29 September 2019 |
System Age (yr): | 1.8 |
Extent of Damage: | Fire |
State During Accident: | Discharging |
Description: | Smoke of an unknown cause occurred in
batteries (Rack#3, Module#9) and battery internal fire occurred as a result of BMS investigation. |
Source: | Social construction of fire accidents in battery energy storage systems in Korea |
Additional Resources: |
- Note: Missing values in this table reflect unknowns.
If you have any details or corrections you would like to contribute to the database please reach out to our Storage Safety email.