Failure Event - Australia, Queensland, Bouldercombe - 26 Sep 2023

From EPRI Storage Wiki
Revision as of 17:16, 20 May 2024 by Jthompson (talk | contribs)
Jump to navigation Jump to search

Overview

Event DetailsSMW-Info-button.png
Location: Australia, Queensland, Bouldercombe
Capacity (MW): 50
Capacity (MWh): 100
Battery Module: Tesla
Integrator: Tesla
Application:
Installation: Substation
Enclosure Type: Integrated products
Event Date: 26 September 2023
System Age (yr): 0.1
Extent of Damage: Single container on fire, possible damage to surrounding containers
State During Accident: Operational
Description:
Root Cause: Integration, Construction, or Assembly
Failed Element: Balance of plant
Source: ABC News
Additional Resources: The Guardian
Inside EVs
Note: Missing values in this table reflect unknowns.

If you have any details or corrections you would like to contribute to the database please reach out to our Storage Safety email.