Failure Event - South Korea, Hadong - 21 Oct 2019

From EPRI Storage Wiki
Revision as of 20:21, 16 May 2024 by Jthompson (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Overview

Event DetailsSMW-Info-button.png
Location: South Korea, Hadong
Capacity (MW):
Capacity (MWh): 1.3
Battery Module:
Integrator:
Application: Solar Integration
Installation: Mountains
Enclosure Type: Prefab
Event Date: 21 October 2019
System Age (yr): 1.2
Extent of Damage: Fire
State During Accident: Charged, inactive
Description: A sudden deterioration in insulation

performance first occurred on BSC#1, followed by a gradual deterioration on the other side (BSC#2), resulting in a fire .

Root Cause: Integration, Construction, or Assembly
Failed Element: Balance of Plant
Source: Social construction of fire accidents in battery energy storage systems in Korea
Additional Resources:
Note: Missing values in this table reflect unknowns.

If you have any details or corrections you would like to contribute to the database please reach out to our Storage Safety email.