	<entry>
		<id>http://storagewiki.epri.com/index.php?title=DER_VET_User_Guide/Technologies/Electrolyzer_System&amp;diff=5478&amp;oldid=prev</id>
		<title>AndrewEtringer: /* Inputs */</title>
		<link rel="alternate" type="text/html" href="http://storagewiki.epri.com/index.php?title=DER_VET_User_Guide/Technologies/Electrolyzer_System&amp;diff=5478&amp;oldid=prev"/>
		<updated>2024-12-18T18:56:41Z</updated>

		<summary type="html">&lt;p&gt;&lt;span dir=&quot;auto&quot;&gt;&lt;span class=&quot;autocomment&quot;&gt;Inputs&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 14:56, 18 December 2024&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l44&quot;&gt;Line 44:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 44:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|min_power&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|min_power&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|The minimum power an electrolyzer system can produce in kW.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|The minimum power an electrolyzer system can produce in kW.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|}&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;== Minimum Power ==&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;{| class=&#039;wikitable&#039; style=&quot;width: 95%;&quot;&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|-&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|style=&quot;width: 10%&quot;|Tag&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|style=&quot;width: 20%&quot;|Key&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|style=&quot;width: 70%&quot;|Description&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|-&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|ElectrolyzerSystem&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|min_rated_power&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|The minimum allowed power in kW, if DER-VET is sizing the Electrolyzer System. Set to 0 to ignore.&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|}&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;== Maximum Power ==&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;{| class=&#039;wikitable&#039; style=&quot;width: 95%;&quot;&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|-&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|style=&quot;width: 10%&quot;|Tag&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|style=&quot;width: 20%&quot;|Key&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|style=&quot;width: 70%&quot;|Description&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|-&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|ElectrolyzerSystem&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|max_rated_power&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|The maximum allowed power in kW, if DER-VET is sizing the Electrolyzer System. Set to 0 to ignore.&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|}&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|}&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br/&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br/&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>AndrewEtringer</name></author>
	</entry>
	<entry>
		<id>http://storagewiki.epri.com/index.php?title=DER_VET_User_Guide/Technologies/Electrolyzer_System&amp;diff=5474&amp;oldid=prev</id>
		<title>AndrewEtringer: adds more details on efficiency and degradation</title>
		<link rel="alternate" type="text/html" href="http://storagewiki.epri.com/index.php?title=DER_VET_User_Guide/Technologies/Electrolyzer_System&amp;diff=5474&amp;oldid=prev"/>
		<updated>2024-12-18T02:53:26Z</updated>

		<summary type="html">&lt;p&gt;adds more details on efficiency and degradation&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{{DISPLAYTITLE: {{SUBPAGENAME}}}}&lt;br /&gt;
&lt;br /&gt;
The Electrolyzer System employed by DER-VET is modeled as a technology that consumes electricity to produce hydrogen. &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Hydrogen Schedule ==&lt;br /&gt;
To define how to control the amount of hydrogen production, the user may select up to 3 modes. These are explained below under Hydrogen Schedule.&lt;br /&gt;
&lt;br /&gt;
== Efficiency ==&lt;br /&gt;
Efficiency can be handled in two ways: as a fixed value across all times, or as a post-optimization calculation using the actual amount of hydrogen produced from a variable efficiency. When incl_variable_efficiency is ON, a calculated variable efficiency will replace the constant scalar efficiency, but only in post-optimization. Two new columns of data will appear in the Time series Output Results CSV: &amp;#039;Efficiency Actual (kg/kWh)&amp;#039; and &amp;#039;Hydrogen Production Actual (kg)&amp;#039;. The new values of Hydrogen Production Actual are then used in performance and financial results. The reason for this treatment is that with variable efficiency ON, using it will create a nonlinear constraint and will break our optimization approach. Instead, we must handle it post-optimization. Note that the calculation of LCOH (Levelized Cost of Hydrogen), which appears in the payback.csv output file, will also use the new values of Hydrogen Production Actual.&lt;br /&gt;
&lt;br /&gt;
== Degradation ==&lt;br /&gt;
When the boolean parameter incl_degradation is ON, both calendar degradation and cycle degradation will be considered. Calendar degradation is set with the yearly_degrade parameter while cycle degradation is calculated using a cycle_life_filename input file. Degradation due to cycling for an Electrolyzer System is handled similarly to how Battery cycling degradation. The notable differences are listed below. For an Electrolyzer System:&lt;br /&gt;
*we do not consider user inputs for state_of_health or cycle_life_table_eol_condition, but instead treat these as zero.  &lt;br /&gt;
*the end-of-life is when the SOH goes to zero.&lt;br /&gt;
*we use power fluctuation (as a percentage of rated_power), and not energy.&lt;br /&gt;
&lt;br /&gt;
Note that DER-VET disallows having both Electrolyzer System sizing and degradation active in the same case.   &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Inputs =&lt;br /&gt;
== Rated Power ==&lt;br /&gt;
{| class=&amp;#039;wikitable&amp;#039; style=&amp;quot;width: 95%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|style=&amp;quot;width: 10%&amp;quot;|Tag&lt;br /&gt;
|style=&amp;quot;width: 20%&amp;quot;|Key&lt;br /&gt;
|style=&amp;quot;width: 70%&amp;quot;|Description&lt;br /&gt;
|-&lt;br /&gt;
|ElectrolyzerSystem&lt;br /&gt;
|rated_power&lt;br /&gt;
|This input sets the power capacity of the electrolyzer system in kW.&lt;br /&gt;
&lt;br /&gt;
Set this to 0 to have DER-VET optimally size this parameter.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Minimum Power ==&lt;br /&gt;
{| class=&amp;#039;wikitable&amp;#039; style=&amp;quot;width: 95%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|style=&amp;quot;width: 10%&amp;quot;|Tag&lt;br /&gt;
|style=&amp;quot;width: 20%&amp;quot;|Key&lt;br /&gt;
|style=&amp;quot;width: 70%&amp;quot;|Description&lt;br /&gt;
|-&lt;br /&gt;
|ElectrolyzerSystem&lt;br /&gt;
|min_power&lt;br /&gt;
|The minimum power an electrolyzer system can produce in kW.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Minimum Power ==&lt;br /&gt;
{| class=&amp;#039;wikitable&amp;#039; style=&amp;quot;width: 95%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|style=&amp;quot;width: 10%&amp;quot;|Tag&lt;br /&gt;
|style=&amp;quot;width: 20%&amp;quot;|Key&lt;br /&gt;
|style=&amp;quot;width: 70%&amp;quot;|Description&lt;br /&gt;
|-&lt;br /&gt;
|ElectrolyzerSystem&lt;br /&gt;
|min_rated_power&lt;br /&gt;
|The minimum allowed power in kW, if DER-VET is sizing the Electrolyzer System. Set to 0 to ignore.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Maximum Power ==&lt;br /&gt;
{| class=&amp;#039;wikitable&amp;#039; style=&amp;quot;width: 95%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|style=&amp;quot;width: 10%&amp;quot;|Tag&lt;br /&gt;
|style=&amp;quot;width: 20%&amp;quot;|Key&lt;br /&gt;
|style=&amp;quot;width: 70%&amp;quot;|Description&lt;br /&gt;
|-&lt;br /&gt;
|ElectrolyzerSystem&lt;br /&gt;
|max_rated_power&lt;br /&gt;
|The maximum allowed power in kW, if DER-VET is sizing the Electrolyzer System. Set to 0 to ignore.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Hydrogen Schedule ==&lt;br /&gt;
{| class=&amp;#039;wikitable&amp;#039; style=&amp;quot;width: 95%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|style=&amp;quot;width: 10%&amp;quot;|Tag&lt;br /&gt;
|style=&amp;quot;width: 20%&amp;quot;|Key&lt;br /&gt;
|style=&amp;quot;width: 70%&amp;quot;|Description&lt;br /&gt;
|-&lt;br /&gt;
|ElectrolyzerSystem&lt;br /&gt;
|hydrogen_schedule_mode&lt;br /&gt;
|Defines how to control hydrogen production: &lt;br /&gt;
&lt;br /&gt;
0=no control, &lt;br /&gt;
&lt;br /&gt;
1=apply a fixed schedule according to an input time series of &amp;#039;ElectrolyzerSystem Schedule (kW)&amp;#039;, &lt;br /&gt;
&lt;br /&gt;
2=use hydrogen_production_quota parameter to set the quantity of hydrogen (kg) that must be produced in each optimization window.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Hydrogen Production Quota ==&lt;br /&gt;
{| class=&amp;#039;wikitable&amp;#039; style=&amp;quot;width: 95%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|style=&amp;quot;width: 10%&amp;quot;|Tag&lt;br /&gt;
|style=&amp;quot;width: 20%&amp;quot;|Key&lt;br /&gt;
|style=&amp;quot;width: 70%&amp;quot;|Description&lt;br /&gt;
|-&lt;br /&gt;
|ElectrolyzerSystem&lt;br /&gt;
|hydrogen_production_quota&lt;br /&gt;
|The quantity of hydrogen (in kg) that must be produced in each optimization window. The parameter only becomes active when hydrogen_schedule_mode is set to 2.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Efficiency ==&lt;br /&gt;
{| class=&amp;#039;wikitable&amp;#039; style=&amp;quot;width: 95%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|style=&amp;quot;width: 10%&amp;quot;|Tag&lt;br /&gt;
|style=&amp;quot;width: 20%&amp;quot;|Key&lt;br /&gt;
|style=&amp;quot;width: 70%&amp;quot;|Description&lt;br /&gt;
|-&lt;br /&gt;
|ElectrolyzerSystem&lt;br /&gt;
|efficiency&lt;br /&gt;
|ElectrolyzerSystem efficiency in kg of hydrogen per kWh of energy.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Variable Efficiency ON/OFF ==&lt;br /&gt;
{| class=&amp;#039;wikitable&amp;#039; style=&amp;quot;width: 95%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|style=&amp;quot;width: 10%&amp;quot;|Tag&lt;br /&gt;
|style=&amp;quot;width: 20%&amp;quot;|Key&lt;br /&gt;
|style=&amp;quot;width: 70%&amp;quot;|Description&lt;br /&gt;
|-&lt;br /&gt;
|ElectrolyzerSystem&lt;br /&gt;
|incl_variable_efficiency&lt;br /&gt;
|T or F (boolean) to calculate (as a post-optimization step) the actual amount of hydrogen produced from the actual efficiency, according to an input variable efficiency &amp;#039;turndown&amp;#039; curve.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Variable Efficiency Curve Filename ==&lt;br /&gt;
{| class=&amp;#039;wikitable&amp;#039; style=&amp;quot;width: 95%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|style=&amp;quot;width: 10%&amp;quot;|Tag&lt;br /&gt;
|style=&amp;quot;width: 20%&amp;quot;|Key&lt;br /&gt;
|style=&amp;quot;width: 70%&amp;quot;|Description&lt;br /&gt;
|-&lt;br /&gt;
|ElectrolyzerSystem&lt;br /&gt;
|variable_efficiency_filename&lt;br /&gt;
|This input points to a file containing the turndown curve describing the variable efficiency. The file must have two columns with a header of &amp;#039;Efficiency (kg/kWh),Fractional Power (%)&amp;#039;. Fractional Power represents percentage of full power and values must be between 0 and 1.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Hydrogen Unit Value ==&lt;br /&gt;
{| class=&amp;#039;wikitable&amp;#039; style=&amp;quot;width: 95%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|style=&amp;quot;width: 10%&amp;quot;|Tag&lt;br /&gt;
|style=&amp;quot;width: 20%&amp;quot;|Key&lt;br /&gt;
|style=&amp;quot;width: 70%&amp;quot;|Description&lt;br /&gt;
|-&lt;br /&gt;
|ElectrolyzerSystem&lt;br /&gt;
|hydrogen_unit_value&lt;br /&gt;
|The value of Hydrogen in $ per kg.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Calendar Degradation ==&lt;br /&gt;
{| class=&amp;#039;wikitable&amp;#039; style=&amp;quot;width: 95%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|style=&amp;quot;width: 10%&amp;quot;|Tag&lt;br /&gt;
|style=&amp;quot;width: 20%&amp;quot;|Key&lt;br /&gt;
|style=&amp;quot;width: 70%&amp;quot;|Description&lt;br /&gt;
|-&lt;br /&gt;
|ElectrolyzerSystem&lt;br /&gt;
|yearly_degrade&lt;br /&gt;
|Percent degradation per year. This calendar degradation combines with cycling degradation to get total degradation.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Degradation ON/OFF ==&lt;br /&gt;
{| class=&amp;#039;wikitable&amp;#039; style=&amp;quot;width: 95%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|style=&amp;quot;width: 10%&amp;quot;|Tag&lt;br /&gt;
|style=&amp;quot;width: 20%&amp;quot;|Key&lt;br /&gt;
|style=&amp;quot;width: 70%&amp;quot;|Description&lt;br /&gt;
|-&lt;br /&gt;
|ElectrolyzerSystem&lt;br /&gt;
|incl_degradation&lt;br /&gt;
|T or F (boolean) to include degradation (both calendar degradation and cycle degradation)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Degradation Curve Filename ==&lt;br /&gt;
{| class=&amp;#039;wikitable&amp;#039; style=&amp;quot;width: 95%;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|style=&amp;quot;width: 10%&amp;quot;|Tag&lt;br /&gt;
|style=&amp;quot;width: 20%&amp;quot;|Key&lt;br /&gt;
|style=&amp;quot;width: 70%&amp;quot;|Description&lt;br /&gt;
|-&lt;br /&gt;
|ElectrolyzerSystem&lt;br /&gt;
|cycle_life_filename&lt;br /&gt;
|This input points to a file containing the degradation curve of the electrolyzer system. The file must have two columns with a header of &amp;#039;Power Fluctuation (%),Cycle Life Value (cycles)&amp;#039;. For our rainflow model, defines the buckets and the number of cycles per bucket the ElectrolyzerSystem can withstand before requiring replacement.&lt;br /&gt;