Difference between revisions of "DER VET User Guide/Technologies/Boiler"
Jump to navigation
Jump to search
en>MilesEvans (Created page with "{{Page in progress}}") |
m (→Rated Capacity) |
||
(4 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{ | {{DISPLAYTITLE: {{SUBPAGENAME}}}} | ||
Boilers consume fuel or electricity and produce hot water or steam to serve thermal loads. | |||
= Inputs = | |||
== Rated Capacity == | |||
{| class='wikitable' style="width: 95%;" | |||
|- | |||
|style="width: 10%"|Tag | |||
|style="width: 20%"|Key | |||
|style="width: 70%"|Description | |||
|- | |||
|Boiler | |||
|rated_capacity | |||
|The maximum heating power capacity of the boiler in MMBtu of heating. Optimal sizing is not recommended or tested for a Boiler. | |||
|} | |||
== Maximum Rated Capacity == | |||
{| class='wikitable' style="width: 95%;" | |||
|- | |||
|style="width: 10%"|Tag | |||
|style="width: 20%"|Key | |||
|style="width: 70%"|Description | |||
|- | |||
|Boiler | |||
|max_rated_capacity | |||
|The maximum rated heating power capacity of the boiler in MMBtu of heating that a size optimization is allowed to output when doing size optimization. | |||
|} | |||
== Minimum Rated Capacity == | |||
{| class='wikitable' style="width: 95%;" | |||
|- | |||
|style="width: 10%"|Tag | |||
|style="width: 20%"|Key | |||
|style="width: 70%"|Description | |||
|- | |||
|Boiler | |||
|min_rated_capacity | |||
|The minimum rated heating power capacity of the boiler in MMBtu of heating that a size optimization is allowed to output when doing size optimization. | |||
|} | |||
== Power Source == | |||
{| class='wikitable' style="width: 95%;" | |||
|- | |||
|style="width: 10%"|Tag | |||
|style="width: 20%"|Key | |||
|style="width: 70%"|Description | |||
|- | |||
|Boiler | |||
|power_source | |||
|What supplies power to the boiler. Either 'electricity', or 'natural gas'. | |||
|} | |||
== COP == | |||
{| class='wikitable' style="width: 95%;" | |||
|- | |||
|style="width: 10%"|Tag | |||
|style="width: 20%"|Key | |||
|style="width: 70%"|Description | |||
|- | |||
|Boiler | |||
|coefficient_of_performance | |||
|The ratio of thermal power out to power supplied to the boiler, whatever the source. The higher this number is, the more efficient the boiler is. | |||
|} |
Latest revision as of 14:06, 14 April 2022
Boilers consume fuel or electricity and produce hot water or steam to serve thermal loads.
Inputs
Rated Capacity
Tag | Key | Description |
Boiler | rated_capacity | The maximum heating power capacity of the boiler in MMBtu of heating. Optimal sizing is not recommended or tested for a Boiler. |
Maximum Rated Capacity
Tag | Key | Description |
Boiler | max_rated_capacity | The maximum rated heating power capacity of the boiler in MMBtu of heating that a size optimization is allowed to output when doing size optimization. |
Minimum Rated Capacity
Tag | Key | Description |
Boiler | min_rated_capacity | The minimum rated heating power capacity of the boiler in MMBtu of heating that a size optimization is allowed to output when doing size optimization. |
Power Source
Tag | Key | Description |
Boiler | power_source | What supplies power to the boiler. Either 'electricity', or 'natural gas'. |
COP
Tag | Key | Description |
Boiler | coefficient_of_performance | The ratio of thermal power out to power supplied to the boiler, whatever the source. The higher this number is, the more efficient the boiler is. |