Difference between revisions of "Failure Event - Australia, Victoria, Geelong - 30 Jul 2021"

From EPRI Storage Wiki
Jump to navigation Jump to search
(Created page with "=Overview= {| class="wikitable" style="width: 50%; font-size: 90%; border: 1px solid #aaaaaa; background-color: #f9f9f9; color: black; margin-bottom: 0.5em; margin-left: 1em;...")
 
Line 64: Line 64:
  |Has State During Accident=Construction, Commissioning
  |Has State During Accident=Construction, Commissioning
  |Has Source=[https://www.abc.net.au/news/2021-07-30/tesla-battery-fire-moorabool-geelong/100337488 ABC News]
  |Has Source=[https://www.abc.net.au/news/2021-07-30/tesla-battery-fire-moorabool-geelong/100337488 ABC News]
  |Has Additional Resources=
  |Has Additional Resources=[https://electrek.co/2021/07/30/tesla-megapack-caught-fire-giant-battery-project-australia/ Electrek]<br>[https://reneweconomy.com.au/australias-biggest-battery-registered-but-battery-storage-supply-crunch-looms/ Renew Economy]
  |Has Failure Event Category=ESS
  |Has Failure Event Category=ESS
}}
}}


[[Category:Failure Event]]
[[Category:Failure Event]]

Revision as of 12:38, 30 July 2021

Overview

Event DetailsSMW-Info-button.png
Location: Australia, Victoria, Geelong
Capacity (MW): 300
Capacity (MWh): 450
Battery Module: Tesla
Integrator: Tesla
Application: Grid Stability
Installation: Rural
Enclosure Type: Integrated products
Event Date: 30 July 2021
System Age (yr): 0
Extent of Damage: Fires in two Megapacks
State During Accident: Construction, Commissioning
Source: ABC News
Additional Resources: Energy Safe Victoria - Statement of Technical Findings
Electrek
Renew Economy
Country Fire Authority
EPA Victoria
Note: Missing values in this table reflect unknowns.

If you have any details or corrections you would like to contribute to the database please reach out to Dirk Long.