Difference between revisions of "Template:Deployment RACI Nav Table"
Jump to navigation
Jump to search
EulaBillaut (talk | contribs) |
|||
| (8 intermediate revisions by 2 users not shown) | |||
| Line 5: | Line 5: | ||
== Template preview == | == Template preview == | ||
</noinclude> | </noinclude>{| class="wikitable" | ||
{| class="wikitable" | |||
|+ | |+ | ||
! Chapter 4: Deployment & Integration - Outline and RACI Matrix | ! Chapter 4: Deployment & Integration - Outline and RACI Matrix | ||
| Line 15: | Line 13: | ||
! Operations | ! Operations | ||
! Legal | ! Legal | ||
! IT / OT / | ! IT / OT / Cybersecurity | ||
! | ! Land / Environment | ||
! Community Affairs | |||
! Supply Chain | ! Supply Chain | ||
! Corporate Mgmt. | ! Corporate Mgmt. | ||
|- | |- | ||
| colspan=" | | colspan="11" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Engineering_&_Permitting|'''Engineering and Permitting''']] | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/ | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Site_Engineering|Site Engineering]] | ||
| style="text-align: center;" | A | | style="text-align: center;" | A | ||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| Line 29: | Line 28: | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | | | style="text-align: center;" | R | ||
| style="text-align: center;" | - | |||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | - | | style="text-align: center;" | - | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/ | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#System_Engineering|System Engineering]] | ||
| style="text-align: center;" | A | | style="text-align: center;" | A | ||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| Line 41: | Line 41: | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | - | | style="text-align: center;" | - | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | - | | style="text-align: center;" | - | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/ | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Permitting_and_Applicable_Codes,_Standards,_and_Regulations_(CSRs)|Permitting]] | ||
| style="text-align: center;" | A | | style="text-align: center;" | A | ||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| Line 63: | Line 53: | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/ | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Factory_Acceptance_Testing|Factory Acceptance Test]] | ||
| style="text-align: center;" | A | | style="text-align: center;" | A | ||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| Line 74: | Line 65: | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | - | |||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/ | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Shipping_and_Receiving|Shipping and Receiving]] | ||
| style="text-align: center;" | A | | style="text-align: center;" | A | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| Line 85: | Line 77: | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
|- | |- | ||
| colspan=" | | colspan="11" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Installation_and_Integration|'''Installation and Integration''']] | ||
|- | |- | ||
[[Utility_BESS_Handbook/ | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Construction_Management|Construction Management]] | ||
| style="text-align: center;" | A | | style="text-align: center;" | A | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| Line 97: | Line 90: | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | |||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | - | | style="text-align: center;" | - | ||
|- | |- | ||
| [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Commissioning|'''Commissioning''']] | |||
| style="text-align: center;" | A | | style="text-align: center;" | A | ||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| Line 107: | Line 101: | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | | | style="text-align: center;" | R | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
|- | |- | ||
| [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Interconnection|'''Interconnection''']] | |||
| style="text-align: center;" | A | | style="text-align: center;" | A | ||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| Line 120: | Line 115: | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | - | |||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
|- | |- | ||
[[Utility_BESS_Handbook/ | | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Deployment Resources|'''Additional Resources''']] | ||
|} | |} | ||
Latest revision as of 16:56, 19 December 2025
This is the "Deployment RACI Nav Table" template used to quickly and concisely add this RACI Nav Table to a page.
To use this, place
{{Deployment RACI Nav Table}}in the desired location on a page.
Template preview
| Chapter 4: Deployment & Integration - Outline and RACI Matrix | Project Mgmt. | Engineering | Safety | Operations | Legal | IT / OT / Cybersecurity | Land / Environment | Community Affairs | Supply Chain | Corporate Mgmt. |
|---|---|---|---|---|---|---|---|---|---|---|
| Engineering and Permitting | ||||||||||
| Site Engineering | A | R | C | C | I | C | R | - | C | - |
| System Engineering | A | R | C | C | I | C | I | - | C | - |
| Permitting | A | R | I | I | C | I | C | I | C | I |
| Factory Acceptance Test | A | R | C | C | I | C | I | - | R | I |
| Shipping and Receiving | A | C | C | R | I | I | C | I | R | I |
| Installation and Integration | ||||||||||
| Construction Management | A | C | C | R | C | I | C | C | C | - |
| Commissioning | A | R | C | C | I | R | I | I | I | I |
| Interconnection | A | R | C | C | C | C | I | - | I | I |
| Additional Resources | ||||||||||