Difference between revisions of "Template:Planning RACI Nav Table"
Jump to navigation
Jump to search
| (7 intermediate revisions by 2 users not shown) | |||
| Line 9: | Line 9: | ||
{| class="wikitable" | {| class="wikitable" | ||
|+ | |+ | ||
! Planning | ! Chapter 2: Planning - Outline and RACI Matrix | ||
! Project Mgmt. | ! Project Mgmt. | ||
! Engineering | ! Engineering | ||
| Line 17: | Line 17: | ||
! IT / Cybersecurity | ! IT / Cybersecurity | ||
! Finance | ! Finance | ||
! Land | ! Land / Environment | ||
! Community Affairs | |||
! Planning | ! Planning | ||
! Corporate Mgmt. | ! Corporate Mgmt. | ||
|- | |- | ||
| [[Utility_BESS_Handbook/Handbook_Planning#General_Consideration:_Team_Building,_Participation,_and_Utility_Department_Roles|'''Team Building, Participation, and Utility Dept. Roles''']] | | [[Utility_BESS_Handbook/Handbook_Planning#General_Consideration:_Team_Building,_Participation,_and_Utility_Department_Roles|'''Team Building, Participation, and Utility Dept. Roles''']] | ||
| style="text-align: center;" | | style="text-align: center;" | | | style="text-align: center;" | R/A | ||
| style="text-align: center;" | C | |||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| Line 34: | Line 36: | ||
|- | |- | ||
| [[Utility_BESS_Handbook/Handbook_Planning#Defining_the_Problem_and_Assessing_Energy_Storage_as_a_Solution|'''Define the Problem and Assess Energy Storage as Potential Solution''']] | | [[Utility_BESS_Handbook/Handbook_Planning#Defining_the_Problem_and_Assessing_Energy_Storage_as_a_Solution|'''Define the Problem and Assess Energy Storage as Potential Solution''']] | ||
| style="text-align: center;" | A | |||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| Line 45: | Line 48: | ||
| style="text-align: center;" | - | | style="text-align: center;" | - | ||
|- | |- | ||
| colspan=" | | colspan="12" | [[Utility_BESS_Handbook/Handbook_Planning#Specify_Minimum_Energy_Storage_Solution_Requirements|'''Specify Minimum Energy Storage Solution Requirements''']] | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#Site-specific_Applications_and_Planning|Site Specific Applications and Planning]] | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#Site-specific_Applications_and_Planning|Site Specific Applications and Planning]] | ||
| style="text-align: center;" | A | |||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| Line 60: | Line 64: | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#System-wide_Applications_and_Planning|System-wide Applications and Planning]] | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#System-wide_Applications_and_Planning|System-wide Applications and Planning]] | ||
| style="text-align: center;" | A | |||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| Line 72: | Line 77: | ||
|- | |- | ||
| [[Utility_BESS_Handbook/Handbook_Planning#Evaluating_Technical_Feasibility|'''Evaluate Technical Feasibility''']] | | [[Utility_BESS_Handbook/Handbook_Planning#Evaluating_Technical_Feasibility|'''Evaluate Technical Feasibility''']] | ||
| style="text-align: center;" | A | |||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| Line 78: | Line 83: | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| Line 83: | Line 89: | ||
| style="text-align: center;" | - | | style="text-align: center;" | - | ||
|- | |- | ||
| colspan=" | | colspan="12" | [[Utility_BESS_Handbook/Handbook_Planning#Finalizing_Case-Specific_Requirements_of_Battery_Energy_Storage|'''Finalize Case-Specific Requirements of Energy Storage''']] | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#Energy_Storage_Asset_Ownership|Energy Storage Asset Ownership]] | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#Energy_Storage_Asset_Ownership|Energy Storage Asset Ownership]] | ||
| style="text-align: center;" | A | |||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| Line 93: | Line 99: | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| Line 98: | Line 105: | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#Energy_Storage_System_Performance_Specification|Energy Storage System Performance]] | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#Energy_Storage_System_Performance_Specification|Energy Storage System Performance]] | ||
| style="text-align: center;" | A | |||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| Line 104: | Line 111: | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| Line 110: | Line 118: | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#Communication,_Control,_and_Cybersecurity_System_Requirements|Communication, Control, and Cybersecurity Requirements]] | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#Communication,_Control,_and_Cybersecurity_System_Requirements|Communication, Control, and Cybersecurity Requirements]] | ||
| style="text-align: center;" | A | |||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | | style="text-align: center;" | C/R | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| Line 122: | Line 131: | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#Site_Requirements_and_Availability|Site Requirements and Availability]] | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#Site_Requirements_and_Availability|Site Requirements and Availability]] | ||
| style="text-align: center;" | A | |||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| Line 129: | Line 138: | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | |||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| Line 134: | Line 144: | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#Local_Constraints|Local Constraints]] | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#Local_Constraints|Local Constraints]] | ||
| style="text-align: center;" | A | |||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| Line 141: | Line 151: | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | |||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| Line 146: | Line 157: | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#Request_for_Information|Request for Information (RFI)]] | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Planning#Request_for_Information|Request for Information (RFI)]] | ||
| style="text-align: center;" | A | |||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| Line 154: | Line 165: | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| style="text-align: center;" | - | | style="text-align: center;" | - | ||
|- | |- | ||
| [[Utility_BESS_Handbook/Handbook_Planning#Financial_Analysis|'''Financial Analysis''']] | | [[Utility_BESS_Handbook/Handbook_Planning#Financial_Analysis|'''Financial Analysis''']] | ||
| style="text-align: center;" | A | |||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| Line 165: | Line 177: | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| Line 170: | Line 183: | ||
|- | |- | ||
| [[Utility_BESS_Handbook/Handbook_Planning#Business_Case|'''Business Case''']] | | [[Utility_BESS_Handbook/Handbook_Planning#Business_Case|'''Business Case''']] | ||
| style="text-align: center;" | A | |||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| Line 177: | Line 190: | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C/R | | style="text-align: center;" | C/R | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
|- | |- | ||
| colspan=" | | colspan="12" | [[Utility_BESS_Handbook/Handbook_Planning#Planning_Resources|'''Additional Planning Resources''']] | ||
|} | |||
Latest revision as of 16:44, 19 December 2025
This is the "Planning RACI Nav Table" template used to quickly and concisely add this RACI Nav Table to a page.
To use this, place
{{Planning RACI Nav Table}}in the desired location on a page.