Difference between revisions of "Template:Deployment RACI Nav Table"

From EPRI Storage Wiki
Jump to navigation Jump to search
 
(4 intermediate revisions by 2 users not shown)
Line 5: Line 5:


== Template preview ==
== Template preview ==
</noinclude>
</noinclude>{| class="wikitable"
 
{| class="wikitable"
|+
|+
! Chapter 4: Deployment & Integration - Outline and RACI Matrix
! Chapter 4: Deployment & Integration - Outline and RACI Matrix
Line 15: Line 13:
! Operations
! Operations
! Legal
! Legal
! IT / OT / Cyber
! IT / OT / Cybersecurity
! Enviro.
! Land / Environment
! Community Affairs
! Supply Chain
! Supply Chain
! Corporate Mgmt.
! Corporate Mgmt.
|-
|-
| colspan="10" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Engineering_&_Permitting|'''Engineering and Permitting''']]
| colspan="11" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Engineering_&_Permitting|'''Engineering and Permitting''']]
|-
|-
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Site_Engineering|Site Engineering]]
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Site_Engineering|Site Engineering]]
Line 29: Line 28:
| style="text-align: center;" | I
| style="text-align: center;" | I
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | R
| style="text-align: center;" | -
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | -
| style="text-align: center;" | -
Line 41: Line 41:
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | I
| style="text-align: center;" | I
| style="text-align: center;" | C
| style="text-align: center;" | -
| style="text-align: center;" | -
|-
| style="padding-left: 2em;" | [[Interconnection Analysis]]
| style="text-align: center;" | A
| style="text-align: center;" | R
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | I
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | -
| style="text-align: center;" | -
Line 63: Line 53:
| style="text-align: center;" | I
| style="text-align: center;" | I
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | I
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | I
| style="text-align: center;" | I
Line 74: Line 65:
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | I
| style="text-align: center;" | I
| style="text-align: center;" | -
| style="text-align: center;" | R
| style="text-align: center;" | R
| style="text-align: center;" | I
| style="text-align: center;" | I
Line 85: Line 77:
| style="text-align: center;" | I
| style="text-align: center;" | I
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | I
| style="text-align: center;" | R
| style="text-align: center;" | R
| style="text-align: center;" | I
| style="text-align: center;" | I
|-
|-
| colspan="10" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Installation_and_Integration|'''Installation and Integration''']]
| colspan="11" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Installation_and_Integration|'''Installation and Integration''']]
|-
|-
| style="padding-left: 2em;" |  
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Construction_Management|Construction Management]]
[[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Construction_Management|Construction Management]]
| style="text-align: center;" | A
| style="text-align: center;" | A
| style="text-align: center;" | C
| style="text-align: center;" | C
Line 98: Line 90:
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | I
| style="text-align: center;" | I
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | C
Line 108: Line 101:
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | I
| style="text-align: center;" | I
| style="text-align: center;" | C
| style="text-align: center;" | R
| style="text-align: center;" | I
| style="text-align: center;" | I
| style="text-align: center;" | I
| style="text-align: center;" | I
| style="text-align: center;" | I
Line 121: Line 115:
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | I
| style="text-align: center;" | I
| style="text-align: center;" | -
| style="text-align: center;" | I
| style="text-align: center;" | I
| style="text-align: center;" | I
| style="text-align: center;" | I
|-
|-
| style="padding-left: 2em;" | [[Performance Testing]]
| [[Utility_BESS_Handbook/Handbook_Deployment_and_Integration#Deployment Resources|'''Additional Resources''']]
| style="text-align: center;" | A
| style="text-align: center;" | R
| style="text-align: center;" | C
| style="text-align: center;" | C
| style="text-align: center;" | I
| style="text-align: center;" | C
| style="text-align: center;" | I
| style="text-align: center;" | I
| style="text-align: center;" | I
|}
|}

Latest revision as of 16:56, 19 December 2025

This is the "Deployment RACI Nav Table" template used to quickly and concisely add this RACI Nav Table to a page.

To use this, place

{{Deployment RACI Nav Table}}

in the desired location on a page.

Template preview

Chapter 4: Deployment & Integration - Outline and RACI Matrix Project Mgmt. Engineering Safety Operations Legal IT / OT / Cybersecurity Land / Environment Community Affairs Supply Chain Corporate Mgmt.
Engineering and Permitting
Site Engineering A R C C I C R - C -
System Engineering A R C C I C I - C -
Permitting A R I I C I C I C I
Factory Acceptance Test A R C C I C I - R I
Shipping and Receiving A C C R I I C I R I
Installation and Integration
Construction Management A C C R C I C C C -
Commissioning A R C C I R I I I I
Interconnection A R C C C C I - I I
Additional Resources