Difference between revisions of "Template:O&M RACI Nav Table"

From EPRI Storage Wiki
Jump to navigation Jump to search
Line 9: Line 9:
{| class="wikitable"
{| class="wikitable"
|+
|+
! O&M
! Chapter 5: O&M - Outline and RACI Matrix
! Project Mgmt.
! Project Mgmt.
! Engineering
! Engineering
Line 29: Line 29:
| style="text-align: center;" | I
| style="text-align: center;" | I
|-
|-
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Optimization_of_BESS|Optimization of BESS]]
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Optimization_of_the_BESS|Optimization of BESS]]
| style="text-align: center;" | A
| style="text-align: center;" | A
| style="text-align: center;" | C
| style="text-align: center;" | C
Line 38: Line 38:
| style="text-align: center;" | I
| style="text-align: center;" | I
|-
|-
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Operations_Coordination_with_Maintenance|Operations' Coordination with Maintenance]]
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Operations%E2%80%99_Coordination_with_Maintenance|Operations' Coordination with Maintenance]]
| style="text-align: center;" | A
| style="text-align: center;" | A
| style="text-align: center;" | C
| style="text-align: center;" | C
Line 74: Line 74:
| style="text-align: center;" | R
| style="text-align: center;" | R
|-
|-
| [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Environmental_Safety_and_Reliability_Reporting|'''Environmental, Safety, and Reliability Reporting''']]
| [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Environmental,_Safety_and_Reliability_Reporting|'''Environmental, Safety, and Reliability Reporting''']]
| style="text-align: center;" | A
| style="text-align: center;" | A
| style="text-align: center;" | C
| style="text-align: center;" | C
Line 82: Line 82:
| style="text-align: center;" | -
| style="text-align: center;" | -
| style="text-align: center;" | C
| style="text-align: center;" | C
|-
| colspan="8" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Operations_and_Maintenance_Resources|'''Additional_O&M_Resources''']]
|}

Revision as of 09:55, 7 September 2023

This is the "O&M RACI Nav Table" template used to quickly and concisely add this RACI Nav Table to a page.

To use this, place

{{O&M RACI Nav Table}}

in the desired location on a page.

Template preview

Chapter 5: O&M - Outline and RACI Matrix Project Mgmt. Engineering Safety Operations Legal IT / OT Cybersecurity Maintenance / Service
Handoff to Operations
Operational Data Management A C I R - I I
Optimization of BESS A C I R - I I
Operations' Coordination with Maintenance A C C R - C R
Maintenance A C/R C C/R - - C/R
Recommissioning A C/R I R - I C/R
Safety A R R R C C R
Environmental, Safety, and Reliability Reporting A C R C C - C
Additional_O&M_Resources