Energy Storage Analysis Case Studies: Difference between revisions

From EPRI Storage Wiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 11: Line 11:
{{#ask:
{{#ask:
  [[Category:Analysis]]
  [[Category:Analysis]]
  <!--|mainlabel=- -->
  |mainlabel=-
  |?Has Title=Title
  |?Has Page=Title
  |?Has Type=Type
  |?Has Use Case Type=Type
  |limit=500
  |limit=500
  |sort=Has Type
  |sort=Has Type

Revision as of 12:32, 6 March 2024

Analysis Case Studies.png

This section of the wiki contains a collection of energy storage valuation and feasibility studies that represent some of the most relevant applications for storage on an ongoing basis. Each of the analyses in this report is based on a real case study performed by EPRI. These analyses pair the Storage Value Estimation Tool(StorageVET®) or the Distributed Energy Resources Value Estimation Tool (DER-VET™) with other grid simulation tools and analysis techniques to establish the optimal size, best use of, expected value of, or technical requirements for energy storage in a range of use cases, including distribution deferral, transmission deferral, renewables integration, market participation, and microgrid applications.

For a more detailed discussion of energy storage modeling, valuation, and available tools, see the Energy Storage Valuation page.

The analysis case studies are divided into categories below.



Description Category
Energy Storage to Offset Need for New Transmission Transmission
Stacking Reliability with System-Level Services from Energy Storage Customer
Distribution Upgrade Deferral with Energy Storage Screening Analysis Distribution
Feasibility of Large Storage with High Renewable Penetration Wholesale
Customer Reliability (Backup) from Economically-Optimal Storage Customer
Large-Scale Solar PV Plus Storage Siting Analysis and Market Participation Wholesale
Increase PV Hosting Capacity with Energy Storage Distribution
Distribution Reliability Improvement (Backup) from Energy Storage Distribution
Distribution Capacity from Energy Storage and Demand Side Management Distribution
Distribution Capacity from Energy Storage Distribution
Decarbonizing Resilience Reliability and Resilience
Military Installation Microgrids Reliability and Resilience
Combined Heat and Power Customer
Emissions in Dispatch Optimization Wholesale
Valuation of Hydrogen Technology on the Electric Grid Using Production Cost Modeling Wholesale
Value Streams in ConEd Territory Wholesale
Eskom Battery Energy Storage System Assessment Case Study Distribution



PRIMARY AUDIENCE: Utilities who are exploring use cases for energy storage systems

KEY RESEARCH QUESTION: What are the high-value applications and associated limitations for energy storage systems on an ongoing basis as demonstrated by contemporary, relevant case studies?

RESEARCH OVERVIEW: The Storage Value Estimation Tool (StorageVET®) or the Distributed Energy Resources Value Estimation Tool (DER-VET™) was used with other grid simulation tools and analysis techniques to establish the optimal size, best use of, expected value of, or technical requirements for energy storage in a range of use cases, including distribution deferral, transmission deferral, renewables integration, market participation, and microgrid applications.was used along with transmission and distribution simulation tools and complex analysis methodologies to uncover the value and technical feasibility of energy storage systems in transmission and distribution investment deferral, market participation, and renewables integration use cases.

KEY FINDINGS:

  • There are real examples where the flexibility offered by storage systems can provide an enormous amount of value relative to their cost, but careful identification, planning, and operation are required.
  • When implementing very high penetrations of renewable energy, energy storage can offer a cost-effective and clean method for reconciling intermittent generation and load while maintain grid stability.
  • Reconciling the differences in lifetime between storage systems and other grid assets through an approach like economic carrying cost is critical for establishing a level comparison.

WHY THIS MATTERS: Storage systems benefit from a clear definition of a primary service that is highly valuable, around which flexible, lower-value services can be stacked.

HOW TO APPLY RESULTS: The analyses in this report serve as excellent examples of technical feasibility and valuation studies for energy storage implementation EPRI software such as StorageVET and OpenDSS. They should be treated as model studies that can be replicated by the user for their own purposes. Additionally, they are a clear cross-section of highly relevant, contemporary use cases for energy storage systems that exemplify how valuable the flexibility they offer can be.

LEARNING AND ENGAGEMENT OPPORTUNITIES:

  • DER-VET User Group (2021)
  • Energy Storage Integration Council

EPRI CONTACTS: Miles Evans, Engineer/Scientist, mevans@epri.com

PROGRAM: Energy Storage and Distributed Generation (P94)