Difference between revisions of "Failure Event - UK, Liverpool - 15 Sep 2020"

From EPRI Storage Wiki
Jump to navigation Jump to search
Tag: Reverted
Tag: Manual revert
Line 67: Line 67:
  |Has State During Accident=
  |Has State During Accident=
  |Has Event Description=An explosion occurred before emergency responders were notified. The fire department arrived and contained the fire, which was limited to one out of the three containers, and confirmed end of incident two days later.  
  |Has Event Description=An explosion occurred before emergency responders were notified. The fire department arrived and contained the fire, which was limited to one out of the three containers, and confirmed end of incident two days later.  
|Has Root Cause=Manufacturing
  |Has Source=[https://epri.box.com/s/ro9v9uyekoen9638b9e5etppd97rq113 Investigation Report]
  |Has Source=Investigation Report
  |Has Additional Resources=[https://epri.box.com/shared/static/23frl7k4oo3kjm1gks83qbz9aoh6b5bl.pdf Energy Storage News]
  |Has Additional Resources=Energy Storage News
  |Has Failure Event Category=ESS
  |Has Failure Event Category=ESS
}}
}}


[[Category:Failure Event]]
[[Category:Failure Event]]

Revision as of 13:03, 16 May 2024

Overview

Event DetailsSMW-Info-button.png
Location: UK, Liverpool
Capacity (MW): 20
Capacity (MWh): 10
Battery Module:
Integrator: Orsted
Application: Frequency Regulation
Installation:
Enclosure Type: Container
Event Date: 15 September 2020
System Age (yr): 1.5
Extent of Damage: Explosion
State During Accident:
Description: An explosion occurred before emergency responders were notified. The fire department arrived and contained the fire, which was limited to one out of the three containers, and confirmed end of incident two days later.
Source: Investigation Report
Additional Resources: Energy Storage News
Note: Missing values in this table reflect unknowns.