Template:Procurement RACI Nav Table
Revision as of 15:54, 8 November 2023 by EulaBillaut (talk | contribs)
This is the "Procurement RACI Nav Table" template used to quickly and concisely add this RACI Nav Table to a page.
To use this, place
{{Procurement RACI Nav Table}}in the desired location on a page.
Template preview
| Chapter 3: Procurement - Outline and RACI Matrix | Project Mgmt. | Engineering | Safety | Operations | Legal | IT / Cybersecurity | Enviro. | Supply Chain | Upper Mgmt. |
|---|---|---|---|---|---|---|---|---|---|
| Develop the Request for Proposal (RFP) | |||||||||
| Key project information | A | R/C | I | I | I | I | I | R | I |
| Scope of work & responsibilities | A | R/C | I | I | I | I | I | R | I |
| Technical requirements & specifications | A | R/C | I | I | I | I | I | R | I |
| Deliverables & submittals | A | R/C | I | I | I | I | I | R | I |
| Develop the Evaluation Method | |||||||||
| Specific category scoring | A | R/C | I | I | I | I | I | R | I |
| RFP internal review & release | A | R/C | I | I | I | I | I | R | I |
| Bid Process Management | |||||||||
| Post-release communications | A | R/C | I | I | I | I | I | R | I |
| Bid evaluation | A | R/C | I | I | I | I | I | R | I |
| Contracting and Award | |||||||||
| Project contracting | A | R/C | I | I | I | I | I | R | I |