Failure Event - France, Corsica, Aghione - 6 Apr 2023

From EPRI Storage Wiki
Jump to navigation Jump to search

Overview

Event DetailsSMW-Info-button.png
Location: France, Corsica, Aghione
Capacity (MW): 4
Capacity (MWh): 3.5
Battery Module:
Integrator:
Application: Solar integration
Installation: Solar + storage
Enclosure Type: Indoor container
Event Date: 6 April 2023
System Age (yr):
Extent of Damage: 1 out of 2 containers burned.
State During Accident: Operational
Description: A fire broke out in a BESS container, activating the automatic suppression system. The BESS was at 95% SOC at the time of the fire. Shortly after opening the doors, an explosion occurred, injuring two firefighters. Three firefighters were hospitalized for smoke intoxication. Homes within 500 m were evacuated and 6 houses located 6 km away were put under shelter-in-place. The BESS was cooled with water for ten days. An investigation by BEA-RI is underway.
Root Cause:
Failed Element:
Source: Fire and Rescue service of Haute Corse
Additional Resources:
Note: Missing values in this table reflect unknowns.

If you have any details or corrections you would like to contribute to the database please reach out to our Storage Safety email.