Failure Event - South Korea, Gimhae - 27 Oct 2019
Jump to navigation
Jump to search
Overview
| Event Details | |
|---|---|
| Location: | South Korea, Gimhae |
| Capacity (MW): | |
| Capacity (MWh): | 2.2 |
| Battery Module: | Samsung SDI |
| Integrator: | |
| Application: | Solar Integration |
| Installation: | |
| Enclosure Type: | Prefab |
| Event Date: | 27 October 2019 |
| System Age (yr): | 1.5 |
| Extent of Damage: | |
| State During Accident: | Charged, inactive |
| Description: | A fire occurred in a BESS. In the EMS log record, the voltage deviation of each battery inside the battery rack continuously increased, resulting in thermal runaway. |
| Root Cause: | Operation |
| Failed Element: | Controls |
| Source: | Social construction of fire accidents in battery energy storage systems in Korea |
| Additional Resources: | |
- Note: Missing values in this table reflect unknowns.
If you have any details or corrections you would like to contribute to the database please reach out to our Storage Safety email.