Failure Event - South Korea, Gunwi-gun, Gyeongsangbuk-do - 17 Jan 2022

From EPRI Storage Wiki
Jump to navigation Jump to search

Overview

Event DetailsSMW-Info-button.png
Location: South Korea, Gunwi-gun, Gyeongsangbuk-do
Capacity (MW): 0.45
Capacity (MWh): 1.5
Battery Module: LG Energy Solution
Integrator:
Application: Solar integration
Installation: Rural
Enclosure Type:
Event Date: 17 January 2022
System Age (yr): 3
Extent of Damage: Fully burnt. Explosion
State During Accident: Operation. Fully charged
Description: A fire occurred in a BESS at a solar + storage facility. The fire department arrived after receiving a report of smoke and opened the door of the structure. The fire department described the situation as having a large amount of smoke generated, but no visible flames. Ten minutes after firefighters exited the structure, an explosion occurred. No injuries were reported.
Root Cause: Manufacturing
Failed Element: Controls
Source: E2News
Additional Resources:
Note: Missing values in this table reflect unknowns.

If you have any details or corrections you would like to contribute to the database please reach out to our Storage Safety email.