=EPRI Energy Storage Safety Roadmap Background=
<div class="responsive-imagemap">
<imagemap>
File:Safety Roadmap Bubble Chart.png|thumb|center|700px|Research topics are shown as circles represented with estimated potential improvement to safety of a single system (the size of the circle), estimated required effort to complete (Y-axis), and time frame of applicability (X-axis). Topic titles listed in the table below. To learn more about each Safety Roadmap task click on the bubbles above or links referenced in the table below to view the relevant section within the Battery Storage Fire Safety Roadmap document.
circle 345 652 86 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=8 ST1 – Addressing the Common Explosion Hazard]
circle 285 786 61 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=9 RP1 – Response Plan Guidelines for Existing and Future BESS]
circle 249 712 28 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=9 RP2 – Response Plan Standardization]
circle 853 440 48 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=9 RP3 – Hazard State Identification and Communication]
circle 891 669 34 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=10 RP4 – Contamination Management]
circle 479 781 62 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=10 DT1 – Improving Availability and Applica- tion of 9540A Testing]
circle 586 679 70 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=10 DT2 – Inclusion of Gas Prediction and Deflagration Protection Tools in BESS Design Processes]
circle 596 533 45 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=11 DT3 – Expansion of 9540A Testing to Address Statistical Variation and Multiple Cell Failures]
circle 700 496 78 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=11 DT4 – Guidelines for Selection and Design of Suppression Systems]
circle 490 695 34 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=11 DT5 – Standardized Electrical Controls Reporting]
circle 694 608 86 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=11 DT6 – Failure Modes and Effects Analysis (FMEA) Guidance]
circle 1011 611 60 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=12 DT7 – Integrated System Design Tools]
circle 911 489 53 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=12 DT8 – Adequacy and Inclusion of Thermal Runaway Propagation Prediction Tools in BESS Design Processes]
circle 775 674 43 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=13 TD1 – Robust Electrical Controls]
circle 781 420 33 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=13 TD2 – Detection of State of Thermal Reaction]
circle 1232 267 48 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=13 TD3 – Detection of Future Thermal Runaway Events]
circle 909 399 34 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=13 TD4 – Detection of Deflagration and Toxicity Risks]
circle 843 558 59 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=13 TD5 – Limitation of Propagation Using Thermal Controls]
circle 1095 310 91 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=13 TD6 – Minimization of Thermal Runaway Using Thermal Controls]
circle 1286 123 122 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=14 TD7 – Safe Cells with No Thermal Runaway Potential]
circle 936 549 42 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=14 TD8 – Thermal Runaway Vent Gas Routing Management During Failure]
circle 1017 414 43 [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=14 TD9 – Ignition Control]
</imagemap>
</div>
{| class="wikitable" style="width: 70%;margin: 0 auto;"
! Safety Category
! Topic
|- style="background-color:#f8ba89"
| style="width: 20%" | ST: Special Topics
| style="width: 80%" | [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=8 ST1]: Addressing the common explosion hazard
|- style="background-color:#fbdc89"
| rowspan="4" | RP: Response Plans
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=9 RP1]: Response plan guidelines for existing and future BESS
|- style="background-color:#fbdc89"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=9 RP2]: Response plan standardization
|- style="background-color:#fbdc89"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=9 RP3]: Hazard state identification and communication
|- style="background-color:#fbdc89"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=10 RP4]: Contamination management
|- style="background-color:#a9e2b9"
| rowspan="8" | DT: Design Tools
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=10 DT1]: Improving availability and application of 9540A testing
|- style="background-color:#a9e2b9"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=10 DT2]: Inclusion of gas prediction and deflagration protection tools in BESS design processes
|- style="background-color:#a9e2b9"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=11 DT3]: Expansion of 9540A testing to address statistical variation and multiple cell failures
|- style="background-color:#a9e2b9"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=11 DT4]: Guidelines for selection and design of suppression systems
|- style="background-color:#a9e2b9"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=11 DT5]: Standardized electrical controls reporting
|- style="background-color:#a9e2b9"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=11 DT6]: Failure modes and effects analysis (FMEA) guidance
|- style="background-color:#a9e2b9"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=12 DT7]: Integrated system design tools
|- style="background-color:#a9e2b9"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=12 DT8]: Adequacy and inclusion of thermal runaway propagation prediction tools in BESS design processes
|- style="background-color:#bae2ff"
| rowspan="9" | TD: Technology Development
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=13 TD1]: Robust electrical controls
|- style="background-color:#bae2ff"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=13 TD2]: Detection of state of thermal reaction
|- style="background-color:#bae2ff"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=13 TD3]: Detection of future thermal runaway events
|- style="background-color:#bae2ff"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=13 TD4]: Detection of deflagration and toxicity risks
|- style="background-color:#bae2ff"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=13 TD5]: Limitation of propagation using thermal controls
|- style="background-color:#bae2ff"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=13 TD6]: Minimization of thermal runaway using thermal controls
|- style="background-color:#bae2ff"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=14 TD7]: Safe cells with no thermal runaway potential
|- style="background-color:#bae2ff"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=14 TD8]: Thermal runaway vent gas routing management during failure
|- style="background-color:#bae2ff"
| [https://storagewiki.epri.com/resources/assets/Energy_Storage_Safety_Supplemental/Public/3002022540_Battery%20Storage%20Fire%20Safety%20Roadmap.pdf#page=14 TD9]: Ignition control
|}

Revision as of 10:48, 1 April 2022

Energy Storage Safety Product Submission Form
Comments: Please provide a description of the product (2000 characters max)
0/2000 characters
Safety Technology Category: Help us to understand to what technology category this product belongs (Select all that apply)
  • Sensor
  • Analysis
  • Thermal Barrier
  • Failure Prevention
  • Fire Suppression
  • Explosion Prevention
  • Explosion Mitigation
  • Environmental
  • Other (if multiple, separate with semicolons)
Integration Level: At what level in the energy storage system is this product integrated? (Select all that apply)
  • Cell
  • Module
  • Unit
  • System
  • Site
  • Other (if multiple, separate with semicolons)
EPRI Energy Storage Safety Roadmap Tags: Tag this product with the relevant Safety Roadmap Tags (Select all that apply)
  • ST1 Addressing the common explosion hazard
  • RP1 Response plan guidelines for existing and future BESS
  • RP2 Response plan standardization
  • RP3 Hazard state identification and communication
  • RP4 Contamination management
  • DT1 Improving availability and application of 9540A testing
  • DT2 Inclusion of gas prediction and deflagration protection tools in BESS design processes
  • DT3 Expansion of 9540A testing to address statistical variation and multiple cell failures
  • DT4 Guidelines for selection and design of suppression systems
  • DT5 Standardized electrical controls reporting
  • DT6 Failure modes and effects analysis (FMEA) guidance
  • DT7 Integrated system design tools
  • DT8 Adequacy and inclusion of thermal runaway propagation prediction tools in BESS design processes
  • TD1 Robust electrical controls
  • TD2 Detection of state of thermal reaction
  • TD3 Detection of future thermal runaway events
  • TD4 Detection of deflagration and toxicity risks
  • TD5 Limitation of propagation using thermal controls
  • TD6 Minimization of thermal runaway using thermal controls
  • TD7 Safe cells with no thermal runaway potential
  • TD8 Thermal runaway vent gas routing management during failure
  • TD9 Ignition control
  • I don't know.
Contact Information: So that we can reach out to you with any questions
Organization type:
  • Utility
  • Product vendor
  • System integrator
  • Researcher
  • Other

EPRI Energy Storage Safety Roadmap Background

ST1 – Addressing the Common Explosion HazardRP1 – Response Plan Guidelines for Existing and Future BESSRP2 – Response Plan StandardizationRP3 – Hazard State Identification and CommunicationRP4 – Contamination ManagementDT1 – Improving Availability and Applica- tion of 9540A TestingDT2 – Inclusion of Gas Prediction and Deflagration Protection Tools in BESS Design ProcessesDT3 – Expansion of 9540A Testing to Address Statistical Variation and Multiple Cell FailuresDT4 – Guidelines for Selection and Design of Suppression SystemsDT5 – Standardized Electrical Controls ReportingDT6 – Failure Modes and Effects Analysis (FMEA) GuidanceDT7 – Integrated System Design ToolsDT8 – Adequacy and Inclusion of Thermal Runaway Propagation Prediction Tools in BESS Design ProcessesTD1 – Robust Electrical ControlsTD2 – Detection of State of Thermal ReactionTD3 – Detection of Future Thermal Runaway EventsTD4 – Detection of Deflagration and Toxicity RisksTD5 – Limitation of Propagation Using Thermal ControlsTD6 – Minimization of Thermal Runaway Using Thermal ControlsTD7 – Safe Cells with No Thermal Runaway PotentialTD8 – Thermal Runaway Vent Gas Routing Management During FailureTD9 – Ignition Control
Research topics are shown as circles represented with estimated potential improvement to safety of a single system (the size of the circle), estimated required effort to complete (Y-axis), and time frame of applicability (X-axis). Topic titles listed in the table below. To learn more about each Safety Roadmap task click on the bubbles above or links referenced in the table below to view the relevant section within the Battery Storage Fire Safety Roadmap document.
Safety Category Topic
ST: Special Topics ST1: Addressing the common explosion hazard
RP: Response Plans RP1: Response plan guidelines for existing and future BESS
RP2: Response plan standardization
RP3: Hazard state identification and communication
RP4: Contamination management
DT: Design Tools DT1: Improving availability and application of 9540A testing
DT2: Inclusion of gas prediction and deflagration protection tools in BESS design processes
DT3: Expansion of 9540A testing to address statistical variation and multiple cell failures
DT4: Guidelines for selection and design of suppression systems
DT5: Standardized electrical controls reporting
DT6: Failure modes and effects analysis (FMEA) guidance
DT7: Integrated system design tools
DT8: Adequacy and inclusion of thermal runaway propagation prediction tools in BESS design processes
TD: Technology Development TD1: Robust electrical controls
TD2: Detection of state of thermal reaction
TD3: Detection of future thermal runaway events
TD4: Detection of deflagration and toxicity risks
TD5: Limitation of propagation using thermal controls
TD6: Minimization of thermal runaway using thermal controls
TD7: Safe cells with no thermal runaway potential
TD8: Thermal runaway vent gas routing management during failure
TD9: Ignition control