DER VET User Guide/Technologies/Chiller: Difference between revisions
Jump to navigation
Jump to search
m (1 revision imported) |
m (→Rated Capacity) |
||
| (3 intermediate revisions by 2 users not shown) | |||
| Line 1: | Line 1: | ||
{{ | {{DISPLAYTITLE: {{SUBPAGENAME}}}} | ||
Chillers convert either electric power or thermal power in the form of hot water supplied by a CHP or boiler into cooling thermal power to serve a thermal cooling load. | |||
= Inputs = | |||
== Rated Capacity == | |||
{| class='wikitable' style="width: 95%;" | |||
|- | |||
|style="width: 10%"|Tag | |||
|style="width: 20%"|Key | |||
|style="width: 70%"|Description | |||
|- | |||
|Chiller | |||
|rated_capacity | |||
|The maximum cooling power capacity of the chiller in tons of cooling. Optimal sizing is not recommended or tested for a Chiller. | |||
|} | |||
== Maximum Rated Capacity == | |||
{| class='wikitable' style="width: 95%;" | |||
|- | |||
|style="width: 10%"|Tag | |||
|style="width: 20%"|Key | |||
|style="width: 70%"|Description | |||
|- | |||
|Chiller | |||
|max_rated_capacity | |||
|The maximum rated cooling power capacity of the chiller in tons of cooling that a size optimization is allowed to output when doing size optimization. | |||
|} | |||
== Minimum Rated Capacity == | |||
{| class='wikitable' style="width: 95%;" | |||
|- | |||
|style="width: 10%"|Tag | |||
|style="width: 20%"|Key | |||
|style="width: 70%"|Description | |||
|- | |||
|Chiller | |||
|min_rated_capacity | |||
|The minimum rated cooling power capacity of the chiller in tons of cooling that a size optimization is allowed to output when doing size optimization. | |||
|} | |||
== Power Source == | |||
{| class='wikitable' style="width: 95%;" | |||
|- | |||
|style="width: 10%"|Tag | |||
|style="width: 20%"|Key | |||
|style="width: 70%"|Description | |||
|- | |||
|Chiller | |||
|power_source | |||
|The type of input energy that powers the chiller. Either 'electricity', 'natural gas', or 'heat'. | |||
|} | |||
== COP == | |||
{| class='wikitable' style="width: 95%;" | |||
|- | |||
|style="width: 10%"|Tag | |||
|style="width: 20%"|Key | |||
|style="width: 70%"|Description | |||
|- | |||
|Chiller | |||
|coefficient_of_performance | |||
|The ratio of output cooling power of the chiller to the input power, whatever the power source. The higher this number is, the more efficient the chiller is. | |||
|} | |||
Latest revision as of 13:06, 14 April 2022
Chillers convert either electric power or thermal power in the form of hot water supplied by a CHP or boiler into cooling thermal power to serve a thermal cooling load.
Inputs
Rated Capacity
| Tag | Key | Description |
| Chiller | rated_capacity | The maximum cooling power capacity of the chiller in tons of cooling. Optimal sizing is not recommended or tested for a Chiller. |
Maximum Rated Capacity
| Tag | Key | Description |
| Chiller | max_rated_capacity | The maximum rated cooling power capacity of the chiller in tons of cooling that a size optimization is allowed to output when doing size optimization. |
Minimum Rated Capacity
| Tag | Key | Description |
| Chiller | min_rated_capacity | The minimum rated cooling power capacity of the chiller in tons of cooling that a size optimization is allowed to output when doing size optimization. |
Power Source
| Tag | Key | Description |
| Chiller | power_source | The type of input energy that powers the chiller. Either 'electricity', 'natural gas', or 'heat'. |
COP
| Tag | Key | Description |
| Chiller | coefficient_of_performance | The ratio of output cooling power of the chiller to the input power, whatever the power source. The higher this number is, the more efficient the chiller is. |