DER VET User Guide/Technologies/Boiler: Difference between revisions

From EPRI Storage Wiki
Jump to navigation Jump to search
No edit summary
 
(One intermediate revision by the same user not shown)
Line 4: Line 4:


= Inputs =
= Inputs =
== Rated Capacity ==
{| class='wikitable' style="width: 95%;"
|-
|style="width: 10%"|Tag
|style="width: 20%"|Key
|style="width: 70%"|Description
|-
|Boiler
|rated_capacity
|The maximum heating power capacity of the boiler in MMBtu of heating. Optimal sizing is not recommended or tested for a Boiler.
|}
== Maximum Rated Capacity ==
{| class='wikitable' style="width: 95%;"
|-
|style="width: 10%"|Tag
|style="width: 20%"|Key
|style="width: 70%"|Description
|-
|Boiler
|max_rated_capacity
|The maximum rated heating power capacity of the boiler in MMBtu of heating that a size optimization is allowed to output when doing size optimization.
|}
== Minimum Rated Capacity ==
{| class='wikitable' style="width: 95%;"
|-
|style="width: 10%"|Tag
|style="width: 20%"|Key
|style="width: 70%"|Description
|-
|Boiler
|min_rated_capacity
|The minimum rated heating power capacity of the boiler in MMBtu of heating that a size optimization is allowed to output when doing size optimization.
|}
== Power Source ==
== Power Source ==
{| class='wikitable' style="width: 95%;"
{| class='wikitable' style="width: 95%;"

Latest revision as of 14:06, 14 April 2022


Boilers consume fuel or electricity and produce hot water or steam to serve thermal loads.

Inputs

Rated Capacity

Tag Key Description
Boiler rated_capacity The maximum heating power capacity of the boiler in MMBtu of heating. Optimal sizing is not recommended or tested for a Boiler.

Maximum Rated Capacity

Tag Key Description
Boiler max_rated_capacity The maximum rated heating power capacity of the boiler in MMBtu of heating that a size optimization is allowed to output when doing size optimization.

Minimum Rated Capacity

Tag Key Description
Boiler min_rated_capacity The minimum rated heating power capacity of the boiler in MMBtu of heating that a size optimization is allowed to output when doing size optimization.

Power Source

Tag Key Description
Boiler power_source What supplies power to the boiler. Either 'electricity', or 'natural gas'.

COP

Tag Key Description
Boiler coefficient_of_performance The ratio of thermal power out to power supplied to the boiler, whatever the source. The higher this number is, the more efficient the boiler is.