Difference between revisions of "Template:Decommissioning RACI Nav Table"
Jump to navigation
Jump to search
EulaBillaut (talk | contribs) (Created page with "*IN PROGRESS* == Template preview == </noinclude> {| class="wikitable" |+ ! Chapter 5: O&M - Outline and RACI Matrix ! Project Mgmt. ! Engineering ! Safety ! Operations ! Legal ! IT / OT Cybersecurity ! Maintenance / Service |- | colspan="8" | '''Handoff to Operations''' |- | style="padding-left: 2em;" | Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Operational_Data_Manage...") |
EulaBillaut (talk | contribs) |
||
| Line 6: | Line 6: | ||
{| class="wikitable" | {| class="wikitable" | ||
|+ | |+ | ||
! Chapter | ! Chapter 6: Decommissioning - Outline and RACI Matrix | ||
! Project Mgmt. | ! Project Mgmt. | ||
! Engineering | ! Engineering | ||
| Line 13: | Line 13: | ||
! Legal | ! Legal | ||
! IT / OT Cybersecurity | ! IT / OT Cybersecurity | ||
! | ! Environmental Compliance | ||
! Corporate Sustainability | |||
! Site Manager | |||
|- | |- | ||
| colspan=" | | colspan="10" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Plan_for_Decommissioning|'''Plan for Decommissioning''']] | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/ | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Roles_and_Shared_Responsibilities|Determine roles and scope for decommissioning]] | ||
| style="text-align: center;" | A | | style="text-align: center;" | A/R | ||
| style="text-align: center;" | C | |||
| style="text-align: center;" | C | |||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | R/C | |||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/ | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Considerations_During_Project_Planning_or_Facility_Design|Develop decommissioning plan]] | ||
| style="text-align: center;" | A | | style="text-align: center;" | A | ||
| style="text-align: center;" | R | |||
| style="text-align: center;" | C | |||
| style="text-align: center;" | C | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | C | |||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | R/C | |||
|- | |||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Operations%E2%80%99_Coordination_with_Maintenance|Determine material value and cost of decommissioning at EOL]] | |||
| style="text-align: center;" | A/R | |||
| style="text-align: center;" | R/C | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | |||
| style="text-align: center;" | C | |||
| style="text-align: center;" | C | |||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance# | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Maintenance|Maintain documentation for decommissioning]] | ||
| style="text-align: center;" | A | | style="text-align: center;" | A/R | ||
| style="text-align: center;" | C | |||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | R | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | A/R | |||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance# | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Recommissioning|Onsite preparations]] | ||
| style="text-align: center;" | A | | style="text-align: center;" | A | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | | | style="text-align: center;" | C | ||
| style="text-align: center;" | C | |||
| style="text-align: center;" | C | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | | |||
| style="text-align: center;" | | |||
| style="text-align: center;" | I | | style="text-align: center;" | I | ||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
|- | |- | ||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Safety| | | colspan="10" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Plan_for_Decommissioning|'''Disconnect and Decommission''']] | ||
|- | |||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Safety|Determine end of life condition has been met]] | |||
| style="text-align: center;" | A | | style="text-align: center;" | A | ||
| style="text-align: center;" | C | |||
| style="text-align: center;" | C | |||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
| style="text-align: center;" | | | style="text-align: center;" | I | ||
| style="text-align: center;" | | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
|- | |- | ||
| [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance# | | style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Safety|Execute decommissioning plan]] | ||
| style="text-align: center;" | A | | style="text-align: center;" | A | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | C | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | R | | style="text-align: center;" | R | ||
|- | |||
| colspan="10" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Environmental,_Safety_and_Reliability_Reporting|'''Transport to End Destination''']] | |||
|- | |||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Safety|Package for transport]] | |||
| style="text-align: center;" | A | |||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | C | | style="text-align: center;" | C | ||
| style="text-align: center;" | - | | style="text-align: center;" | I | ||
| style="text-align: center;" | C | | style="text-align: center;" | I | ||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | R | |||
|- | |||
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Safety|Execute decommissioning plan]] | |||
| style="text-align: center;" | A/R | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | C/I | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | C/I | |||
| style="text-align: center;" | I | |||
| style="text-align: center;" | I | |||
|- | |- | ||
| colspan=" | | colspan="10" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Operations_and_Maintenance_Resources|'''Additional Decommissioning Resources''']] | ||
|} | |} | ||
Revision as of 13:12, 23 October 2023
- IN PROGRESS*
Template preview
| Chapter 6: Decommissioning - Outline and RACI Matrix | Project Mgmt. | Engineering | Safety | Operations | Legal | IT / OT Cybersecurity | Environmental Compliance | Corporate Sustainability | Site Manager |
|---|---|---|---|---|---|---|---|---|---|
| Plan for Decommissioning | |||||||||
| Determine roles and scope for decommissioning | A/R | C | C | C | I | I | I | I | R/C |
| Develop decommissioning plan | A | R | C | C | I | I | C | C | R/C |
| Determine material value and cost of decommissioning at EOL | A/R | R/C | I | I | I | I | C | C | C |
| Maintain documentation for decommissioning | A/R | C | C | C | C | I | I | I | A/R |
| Onsite preparations | A | C | C | C | C | I | I | I | R |
| Disconnect and Decommission | |||||||||
| Determine end of life condition has been met | A | C | C | R | I | I | C | C | R |
| Execute decommissioning plan | A | C | C | I | I | I | I | I | R |
| Transport to End Destination | |||||||||
| Package for transport | A | C | C | I | I | I | I | I | R |
| Execute decommissioning plan | A/R | I | I | I | C/I | I | C/I | I | I |
| Additional Decommissioning Resources | |||||||||