Difference between revisions of "Template:Decommissioning RACI Nav Table"

From EPRI Storage Wiki
Jump to navigation Jump to search
 
(8 intermediate revisions by one other user not shown)
Line 1: Line 1:
<noinclude>
This is the "Decommissioning  RACI Nav Table" template used to quickly and concisely add this RACI Nav Table to a page.
To use this, place <pre>{{Decommissioning RACI Nav Table}}</pre> in the desired location on a page.
== Template preview ==
== Template preview ==
</noinclude>
</noinclude>{| class="wikitable"
 
{| class="wikitable"
|+
|+
! Chapter 6: Decommissioning - Outline and RACI Matrix
! Chapter 6: Decommissioning - Outline and RACI Matrix
Line 11: Line 13:
! Legal
! Legal
! IT / OT Cybersecurity
! IT / OT Cybersecurity
! Environmental Compliance
! Land / Environment
! Corporate Sustainability
! Corporate Sustainability
! Site Manager
! Site Manager
Line 17: Line 19:
| colspan="10" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Plan_for_Decommissioning|'''Plan for Decommissioning''']]
| colspan="10" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Plan_for_Decommissioning|'''Plan for Decommissioning''']]
|-
|-
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Roles_and_Shared_Responsibilities|Determine roles and scope for decommissioning]]
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Determine_Roles_for_Decommissioning|Determine roles and scope for decommissioning]]
| style="text-align: center;" | A/R
| style="text-align: center;" | A/R
| style="text-align: center;" | C
| style="text-align: center;" | C
Line 28: Line 30:
| style="text-align: center;" | R/C
| style="text-align: center;" | R/C
|-
|-
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Considerations_During_Project_Planning_or_Facility_Design|Develop decommissioning plan]]
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Develop_a_Decommissioning_Plan|Develop decommissioning plan]]
| style="text-align: center;" | A
| style="text-align: center;" | A
| style="text-align: center;" | R
| style="text-align: center;" | R
Line 39: Line 41:
| style="text-align: center;" | R/C
| style="text-align: center;" | R/C
|-
|-
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Operations%E2%80%99_Coordination_with_Maintenance|Determine material value and cost of decommissioning at EOL]]
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Determine_Material_Value_and_Cost_of_Decommissioning_at_EOL|Determine material value and cost of decommissioning at EOL]]
| style="text-align: center;" | A/R
| style="text-align: center;" | A/R
| style="text-align: center;" | R/C
| style="text-align: center;" | R/C
Line 50: Line 52:
| style="text-align: center;" | C
| style="text-align: center;" | C
|-
|-
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Maintenance|Maintain documentation for decommissioning]]
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Maintain_Documentation_for_Decommissioning|Maintain documentation for decommissioning]]
| style="text-align: center;" | A/R
| style="text-align: center;" | A/R
| style="text-align: center;" | C
| style="text-align: center;" | C
Line 61: Line 63:
| style="text-align: center;" | A/R
| style="text-align: center;" | A/R
|-
|-
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Recommissioning|Onsite preparations]]
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Onsite_Preparations|Onsite preparations]]
| style="text-align: center;" | A
| style="text-align: center;" | A
| style="text-align: center;" | C
| style="text-align: center;" | C
Line 72: Line 74:
| style="text-align: center;" | R
| style="text-align: center;" | R
|-
|-
| colspan="10" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Plan_for_Decommissioning|'''Disconnect and Decommission''']]
| colspan="10" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Disconnect_and_Decommission|'''Disconnect and Decommission''']]
|-
|-
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Safety|Determine end of life condition has been met]]
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Determine_End_of_Life_Condition_is_Met|Determine end of life condition has been met]]
| style="text-align: center;" | A
| style="text-align: center;" | A
| style="text-align: center;" | C
| style="text-align: center;" | C
Line 85: Line 87:
| style="text-align: center;" | R
| style="text-align: center;" | R
|-
|-
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Safety|Execute decommissioning plan]]
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Execute_Decommissioning_Plan|Execute decommissioning plan]]
| style="text-align: center;" | A
| style="text-align: center;" | A
| style="text-align: center;" | C
| style="text-align: center;" | C
Line 96: Line 98:
| style="text-align: center;" | R
| style="text-align: center;" | R
|-
|-
| colspan="10" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Environmental,_Safety_and_Reliability_Reporting|'''Transport to End Destination''']]
| colspan="10" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Equipment_Packaging_and_Transport|'''Transport to End Destination''']]
|-
|-
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Safety|Package for transport]]
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Packaging_for_Transport|Package for transport]]
| style="text-align: center;" | A
| style="text-align: center;" | A
| style="text-align: center;" | C
| style="text-align: center;" | C
Line 109: Line 111:
| style="text-align: center;" | R
| style="text-align: center;" | R
|-
|-
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Safety|Execute decommissioning plan]]
| style="padding-left: 2em;" | [[Utility_BESS_Handbook/Handbook_Decommissioning#Transportation_to_Next_Destination|Transportation to next destination]]
| style="text-align: center;" | A/R
| style="text-align: center;" | A/R
| style="text-align: center;" | I
| style="text-align: center;" | I
Line 120: Line 122:
| style="text-align: center;" | I
| style="text-align: center;" | I
|-
|-
| colspan="10" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Operations_and_Maintenance_Resources|'''Additional Decommissioning Resources''']]
| colspan = "10" | [[Utility_BESS_Handbook/Handbook_Operations_and_Maintenance#Operations_and_Maintenance_Resources|'''Additional Resources''']]
 
|}
|}

Latest revision as of 13:51, 20 December 2024

This is the "Decommissioning RACI Nav Table" template used to quickly and concisely add this RACI Nav Table to a page.

To use this, place

{{Decommissioning RACI Nav Table}}

in the desired location on a page.

Template preview

Chapter 6: Decommissioning - Outline and RACI Matrix Project Mgmt. Engineering Safety Operations Legal IT / OT Cybersecurity Land / Environment Corporate Sustainability Site Manager
Plan for Decommissioning
Determine roles and scope for decommissioning A/R C C C I I I I R/C
Develop decommissioning plan A R C C I I C C R/C
Determine material value and cost of decommissioning at EOL A/R R/C I I I I C C C
Maintain documentation for decommissioning A/R C C C C I I I A/R
Onsite preparations A C C C C I I I R
Disconnect and Decommission
Determine end of life condition has been met A C C R I I C C R
Execute decommissioning plan A C C I I I I I R
Transport to End Destination
Package for transport A C C I I I I I R
Transportation to next destination A/R I I I C/I I C/I I I
Additional Resources