Difference between revisions of "Failure Event - China, Beijing - 16 Apr 2021"
Jump to navigation
Jump to search
Line 50: | Line 50: | ||
:''Note: Missing values in this table reflect unknowns.'' | :''Note: Missing values in this table reflect unknowns.'' | ||
If you have any details or corrections you would like to contribute to the database please reach out to [mailto: | If you have any details or corrections you would like to contribute to the database please reach out to our [mailto:Storage-Safety@epri.com Storage Safety email]. | ||
<!--Set Semantic information for this system--> | <!--Set Semantic information for this system--> |
Revision as of 10:08, 5 July 2022
Overview
Event Details | |
---|---|
Location: | China, Beijing |
Capacity (MW): | |
Capacity (MWh): | 25 |
Battery Module: | Gotion High-Tech [LFP] |
Integrator: | |
Application: | Solar Integration |
Installation: | Commercial |
Enclosure Type: | Container |
Event Date: | 16 April 2021 |
System Age (yr): | 2 |
Extent of Damage: | Explosion |
State During Accident: | Construction, Commissioning |
Description: | A fire broke out at a BESS located on the roof of a shopping mall. An explosion occurred, killing two firefighters and injuring a third. |
Source: | Investigation Report (English Translation) |
Additional Resources: |
- Note: Missing values in this table reflect unknowns.
If you have any details or corrections you would like to contribute to the database please reach out to our Storage Safety email.