Difference between revisions of "Failure Event - Japan, Ibaraki Prefecture - 21 Sep 2011"

From EPRI Storage Wiki
Jump to navigation Jump to search
Line 50: Line 50:
:''Note: Missing values in this table reflect unknowns.''
:''Note: Missing values in this table reflect unknowns.''


If you have any details or corrections you would like to contribute to the database please reach out to [mailto:dlong@epri.com Dirk Long].
If you have any details or corrections you would like to contribute to the database please reach out to our [mailto:Storage-Safety@epri.com Storage Safety email].


<!--Set Semantic information for this system-->
<!--Set Semantic information for this system-->

Revision as of 10:09, 5 July 2022

Overview

Event DetailsSMW-Info-button.png
Location: Japan, Ibaraki Prefecture
Capacity (MW): 2
Capacity (MWh):
Battery Module: NGK [NaS]
Integrator:
Application:
Installation: Industrial
Enclosure Type:
Event Date: 21 September 2011
System Age (yr):
Extent of Damage: Fire
State During Accident:
Description: A sodium-sulfur BESS fire occurred at Mistubishi Material Corp's Tsukuba plant
Source: NGK
Additional Resources: Green Car Congress
Note: Missing values in this table reflect unknowns.