Difference between revisions of "Failure Event - South Korea, Haenam - 27 May 2020"

From EPRI Storage Wiki
Jump to navigation Jump to search
 
Line 55: Line 55:
{{#set:
{{#set:
  Has Location=[[Failure Event - South Korea, Haenam - 27 May 2020|South Korea, Haenam]]
  Has Location=[[Failure Event - South Korea, Haenam - 27 May 2020|South Korea, Haenam]]
  |Has Capacity (MWh)=1.8
  |Has Capacity (MWh)=
  |Has Capacity (MW)=0.5
  |Has Capacity (MW)=
  |Has battery vendor=
  |Has battery vendor=
  |Has Integrator=
  |Has Integrator=
Line 64: Line 64:
  |Has Event Date=05/27/2020
  |Has Event Date=05/27/2020
  |Has System Age (yr)=2.2
  |Has System Age (yr)=2.2
  |Has Extent of Damage=Fire, $400k
  |Has Extent of Damage=Fire
  |Has State During Accident=
  |Has State During Accident=
  |Has Event Description=
  |Has Event Description=The BESS at a solar + storage facility caught fire. The South Korean government had implemented an upper limit of SOC of 90% for outdoor installations at the beginning of the year, but it was confirmed that the company had continued to operate with an upper limit of SOC of 95% as before. The cause is suspected to be battery deterioration due to overcharging or BMS error.
  |Has Source=[http://www.e2news.com/news/articleView.html?idxno=222794 E2News.com]
  |Has Source=[https://epri.box.com/s/0fs9nzeoa7c4ohogrb9qjtsj1yv13eqk E2 News (Translated)]
  |Has Additional Resources=
  |Has Additional Resources=[https://epri.box.com/s/j2w0yuolh5hjddwui6wxe17062j7zp5d E2 News (Original source, Korean)]
  |Has Failure Event Category=ESS
  |Has Failure Event Category=ESS
}}
}}


[[Category:Failure Event]]
[[Category:Failure Event]]

Latest revision as of 12:38, 10 April 2024

Overview

Event DetailsSMW-Info-button.png
Location: South Korea, Haenam
Capacity (MW):
Capacity (MWh):
Battery Module:
Integrator:
Application: Solar Integration
Installation: Field
Enclosure Type: Prefab
Event Date: 27 May 2020
System Age (yr): 2.2
Extent of Damage: Fire
State During Accident:
Description: The BESS at a solar + storage facility caught fire. The South Korean government had implemented an upper limit of SOC of 90% for outdoor installations at the beginning of the year, but it was confirmed that the company had continued to operate with an upper limit of SOC of 95% as before. The cause is suspected to be battery deterioration due to overcharging or BMS error.
Source: E2 News (Translated)
Additional Resources: E2 News (Original source, Korean)
Note: Missing values in this table reflect unknowns.

If you have any details or corrections you would like to contribute to the database please reach out to our Storage Safety email.