Difference between revisions of "Failure Event - US, CA, Moss Landing - 4 Sep 2021"
Jump to navigation
Jump to search
Line 68: | Line 68: | ||
|Has Event Description= | |Has Event Description= | ||
|Has Source=[https://investor.vistracorp.com/news?item=197 Vistra] | |Has Source=[https://investor.vistracorp.com/news?item=197 Vistra] | ||
|Has Additional Resources=[https://pv-magazine-usa.com/2021/09/07/moss-landing-energy-storage-facility-knocked-offline-after-batteries-overheat PV Magazine]<br>[https://vistra.app.box.com/s/1aezfypko93vz5jm9nn9tckphtjkgzvb Vistra Findings and Corrective Actions Report] | |Has Additional Resources=[https://pv-magazine-usa.com/2021/09/07/moss-landing-energy-storage-facility-knocked-offline-after-batteries-overheat%20PV%20Magazine%5d%3cbr%3e%5bhttps:/vistra.app.box.com/s/1aezfypko93vz5jm9nn9tckphtjkgzvb%20Vistra%20Findings%20and%20Corrective%20Actions%20Report [https://pv-magazine-usa.com/2021/09/07/moss-landing-energy-storage-facility-knocked-offline-after-batteries-overheat PV Magazine]<br>[https://vistra.app.box.com/s/1aezfypko93vz5jm9nn9tckphtjkgzvb Vistra Findings and Corrective Actions Report]] | ||
|Has Failure Event Category=ESS | |Has Failure Event Category=ESS | ||
}} | }} | ||
[[Category:Failure Event]] | [[Category:Failure Event]] |
Latest revision as of 12:38, 10 April 2024
Overview
Event Details | |
---|---|
Location: | US, CA, Moss Landing |
Capacity (MW): | 300 |
Capacity (MWh): | 1,200 |
Battery Module: | LG Energy Solution |
Integrator: | Fluence |
Application: | Solar Integration |
Installation: | Power Plant |
Enclosure Type: | |
Event Date: | 4 September 2021 |
System Age (yr): | 0.8 |
Extent of Damage: | Scorched racks, melted wires |
State During Accident: | |
Description: | |
Source: | Vistra |
Additional Resources: | [https://pv-magazine-usa.com/2021/09/07/moss-landing-energy-storage-facility-knocked-offline-after-batteries-overheat PV Magazine Vistra Findings and Corrective Actions Report] |
- Note: Missing values in this table reflect unknowns.
If you have any details or corrections you would like to contribute to the database please reach out to our Storage Safety email.