Overview
Event Details | |
---|---|
Location: | US, CA, Moss Landing |
Capacity (MW): | 300 |
Capacity (MWh): | 1,200 |
Battery Module: | LG Energy Solution |
Integrator: | Fluence |
Application: | Solar Integration |
Installation: | Power Plant |
Enclosure Type: | |
Event Date: | 4 September 2021 |
System Age (yr): | 0.8 |
Extent of Damage: | Scorched racks, melted wires |
State During Accident: | |
Description: | |
Source: | Vistra |
Additional Resources: | [https://pv-magazine-usa.com/2021/09/07/moss-landing-energy-storage-facility-knocked-offline-after-batteries-overheat PV Magazine Vistra Findings and Corrective Actions Report] |
- Note: Missing values in this table reflect unknowns.
If you have any details or corrections you would like to contribute to the database please reach out to our Storage Safety email.